WEKO3
アイテム
{"_buckets": {"deposit": "5743df5f-51ed-4aba-86ee-963779c64caf"}, "_deposit": {"created_by": 2, "id": "1720", "owners": [2], "pid": {"revision_id": 0, "type": "depid", "value": "1720"}, "status": "published"}, "_oai": {"id": "oai:hama-med.repo.nii.ac.jp:00001720", "sets": ["11"]}, "author_link": ["4080", "4084", "4085", "4083", "4082", "4081"], "item_3_alternative_title_1": {"attribute_name": "その他のタイトル", "attribute_value_mlt": [{"subitem_alternative_title": "Sensitive determination of nitriles in human whole blood by cryogenic oven trapping gas chromatography"}]}, "item_3_biblio_info_5": {"attribute_name": "書誌情報", "attribute_value_mlt": [{"bibliographicIssueDates": {"bibliographicIssueDate": "2005-07-01", "bibliographicIssueDateType": "Issued"}, "bibliographicIssueNumber": "2", "bibliographicPageEnd": "109", "bibliographicPageStart": "108", "bibliographicVolumeNumber": "23", "bibliographic_titles": [{"bibliographic_title": "法中毒 = Japanese journal of forensic toxicology"}]}]}, "item_3_description_30": {"attribute_name": "フォーマット", "attribute_value_mlt": [{"subitem_description": "application/pdf", "subitem_description_type": "Other"}]}, "item_3_description_9": {"attribute_name": "抄録", "attribute_value_mlt": [{"subitem_description": "We have developed a simple and sensitive method for determining acetonitrile and propionitrile in human whole blood using capillary gas chromatography (GC) with cryogenic oven trapping. After heating 0.5 mL of a whole blood sample containing both nitriles and 0.5 mL distilled water in a 7-mL vial at 75℃ for 15min, 5 mL of the headspace vapor was drawn into a 10-mL syringe and injected to GC with a flame thermionic detector. A sharp peak was obtained for acetonitrile at -10℃ of the initial oven temperature. The extraction efficiencies for acetonitrile and propionitrile were 0.27 and 0.40%, respectively. For quantitation of acetonitrile, propionitrile was used as internal standard, and vise versa. The calibration curves for both compounds gave good linearity in the range of 0.2-6 μg/mL whole blood. The detection limits (signal to noise ratio = 3) were 0.05μg/mL for acetonitrile and 0.01μg/mL for propionitrile. The coefficients of intra-day variations were 1.0% at 0.4μg/mL and 1.7% at 2μg/mL for acetonitrile; 7.1% at 0.4μg/mL and 1.0% at 2 μg/mL for propionitrile. Thus, this method can be applicable for determining these nitriles in whole blood samples in acute and chronic intoxication cases.", "subitem_description_type": "Abstract"}]}, "item_3_publisher_6": {"attribute_name": "出版者", "attribute_value_mlt": [{"subitem_publisher": "日本法中毒学会"}]}, "item_3_rights_7": {"attribute_name": "権利", "attribute_value_mlt": [{"subitem_rights": "© 日本法中毒学会"}, {"subitem_rights": "本文データは日本法中毒学会の許諾のもと掲載しています。"}]}, "item_3_select_2": {"attribute_name": "資源タイプ", "attribute_value_mlt": [{"subitem_select_item": "Journal Article"}]}, "item_3_source_id_19": {"attribute_name": "ISSN", "attribute_value_mlt": [{"subitem_source_identifier": "09159606", "subitem_source_identifier_type": "ISSN"}]}, "item_3_version_type_32": {"attribute_name": "著者版フラグ", "attribute_value_mlt": [{"subitem_version_resource": "http://purl.org/coar/version/c_970fb48d4fbd8a85", "subitem_version_type": "VoR"}]}, "item_creator": {"attribute_name": "著者", "attribute_type": "creator", "attribute_value_mlt": [{"creatorNames": [{"creatorName": "金子, 理奈"}], "nameIdentifiers": [{"nameIdentifier": "4080", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "福居, 玲奈"}], "nameIdentifiers": [{"nameIdentifier": "4081", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "平田, ゆかり"}], "nameIdentifiers": [{"nameIdentifier": "4082", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "浜島, 誠"}], "nameIdentifiers": [{"nameIdentifier": "4083", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "渡部, 加奈子"}], "nameIdentifiers": [{"nameIdentifier": "4084", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "石井, 晃"}], "nameIdentifiers": [{"nameIdentifier": "4085", "nameIdentifierScheme": "WEKO"}]}]}, "item_files": {"attribute_name": "ファイル情報", "attribute_type": "file", "attribute_value_mlt": [{"accessrole": "open_date", "date": [{"dateType": "Available", "dateValue": "2018-08-27"}], "displaytype": "detail", "download_preview_message": "", "file_order": 0, "filename": "FT-23-108.pdf", "filesize": [{"value": "110.3 kB"}], "format": "application/pdf", "future_date_message": "", "is_thumbnail": false, "licensetype": "license_free", "mimetype": "application/pdf", "size": 110300.0, "url": {"label": "FT-23-108.pdf", "url": "https://hama-med.repo.nii.ac.jp/record/1720/files/FT-23-108.pdf"}, "version_id": "b607ac4f-53b7-4bf2-8262-727527121fb2"}]}, "item_language": {"attribute_name": "言語", "attribute_value_mlt": [{"subitem_language": "jpn"}]}, "item_resource_type": {"attribute_name": "資源タイプ", "attribute_value_mlt": [{"resourcetype": "journal article", "resourceuri": "http://purl.org/coar/resource_type/c_6501"}]}, "item_title": "低温オーブントラッピングガスクロマトグラフィーによるヒト全血中アセトニトリル及びプロピオニトリルの高感度分析", "item_titles": {"attribute_name": "タイトル", "attribute_value_mlt": [{"subitem_title": "低温オーブントラッピングガスクロマトグラフィーによるヒト全血中アセトニトリル及びプロピオニトリルの高感度分析"}]}, "item_type_id": "3", "owner": "2", "path": ["11"], "permalink_uri": "http://hdl.handle.net/10271/1753", "pubdate": {"attribute_name": "公開日", "attribute_value": "2013-08-27"}, "publish_date": "2013-08-27", "publish_status": "0", "recid": "1720", "relation": {}, "relation_version_is_last": true, "title": ["低温オーブントラッピングガスクロマトグラフィーによるヒト全血中アセトニトリル及びプロピオニトリルの高感度分析"], "weko_shared_id": -1}
低温オーブントラッピングガスクロマトグラフィーによるヒト全血中アセトニトリル及びプロピオニトリルの高感度分析
http://hdl.handle.net/10271/1753
http://hdl.handle.net/10271/175372c4c1b4-0b67-4895-bea9-22ec21e130ec
名前 / ファイル | ライセンス | アクション |
---|---|---|
FT-23-108.pdf (110.3 kB)
|
|
Item type | 学術雑誌論文 / Journal Article(1) | |||||
---|---|---|---|---|---|---|
公開日 | 2013-08-27 | |||||
タイトル | ||||||
タイトル | 低温オーブントラッピングガスクロマトグラフィーによるヒト全血中アセトニトリル及びプロピオニトリルの高感度分析 | |||||
言語 | ||||||
言語 | jpn | |||||
資源タイプ | ||||||
資源タイプ識別子 | http://purl.org/coar/resource_type/c_6501 | |||||
資源タイプ | journal article | |||||
その他のタイトル | ||||||
その他のタイトル | Sensitive determination of nitriles in human whole blood by cryogenic oven trapping gas chromatography | |||||
著者 |
金子, 理奈
× 金子, 理奈× 福居, 玲奈× 平田, ゆかり× 浜島, 誠× 渡部, 加奈子× 石井, 晃 |
|||||
書誌情報 |
法中毒 = Japanese journal of forensic toxicology 巻 23, 号 2, p. 108-109, 発行日 2005-07-01 |
|||||
出版者 | ||||||
出版者 | 日本法中毒学会 | |||||
権利 | ||||||
権利情報 | © 日本法中毒学会 | |||||
権利 | ||||||
権利情報 | 本文データは日本法中毒学会の許諾のもと掲載しています。 | |||||
抄録 | ||||||
内容記述タイプ | Abstract | |||||
内容記述 | We have developed a simple and sensitive method for determining acetonitrile and propionitrile in human whole blood using capillary gas chromatography (GC) with cryogenic oven trapping. After heating 0.5 mL of a whole blood sample containing both nitriles and 0.5 mL distilled water in a 7-mL vial at 75℃ for 15min, 5 mL of the headspace vapor was drawn into a 10-mL syringe and injected to GC with a flame thermionic detector. A sharp peak was obtained for acetonitrile at -10℃ of the initial oven temperature. The extraction efficiencies for acetonitrile and propionitrile were 0.27 and 0.40%, respectively. For quantitation of acetonitrile, propionitrile was used as internal standard, and vise versa. The calibration curves for both compounds gave good linearity in the range of 0.2-6 μg/mL whole blood. The detection limits (signal to noise ratio = 3) were 0.05μg/mL for acetonitrile and 0.01μg/mL for propionitrile. The coefficients of intra-day variations were 1.0% at 0.4μg/mL and 1.7% at 2μg/mL for acetonitrile; 7.1% at 0.4μg/mL and 1.0% at 2 μg/mL for propionitrile. Thus, this method can be applicable for determining these nitriles in whole blood samples in acute and chronic intoxication cases. | |||||
ISSN | ||||||
収録物識別子タイプ | ISSN | |||||
収録物識別子 | 09159606 | |||||
著者版フラグ | ||||||
出版タイプ | VoR | |||||
出版タイプResource | http://purl.org/coar/version/c_970fb48d4fbd8a85 |