<?xml version='1.0' encoding='UTF-8'?>
<OAI-PMH xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/ http://www.openarchives.org/OAI/2.0/OAI-PMH.xsd">
  <responseDate>2026-03-07T03:48:35Z</responseDate>
  <request verb="GetRecord" metadataPrefix="jpcoar_2.0" identifier="oai:hama-med.repo.nii.ac.jp:00001718">https://hama-med.repo.nii.ac.jp/oai</request>
  <GetRecord>
    <record>
      <header>
        <identifier>oai:hama-med.repo.nii.ac.jp:00001718</identifier>
        <datestamp>2023-08-02T04:01:15Z</datestamp>
        <setSpec>1:11</setSpec>
      </header>
      <metadata>
        <jpcoar:jpcoar xmlns:datacite="https://schema.datacite.org/meta/kernel-4/" xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:dcndl="http://ndl.go.jp/dcndl/terms/" xmlns:dcterms="http://purl.org/dc/terms/" xmlns:jpcoar="https://github.com/JPCOAR/schema/blob/master/2.0/" xmlns:oaire="http://namespace.openaire.eu/schema/oaire/" xmlns:rdf="http://www.w3.org/1999/02/22-rdf-syntax-ns#" xmlns:rioxxterms="http://www.rioxx.net/schema/v2.0/rioxxterms/" xmlns:xs="http://www.w3.org/2001/XMLSchema" xmlns="https://github.com/JPCOAR/schema/blob/master/2.0/" xsi:schemaLocation="https://github.com/JPCOAR/schema/blob/master/2.0/jpcoar_scm.xsd">
          <dc:title xml:lang="en">SENSITIVE DETERMINATION OF ACETONITRILE AND PROPIONITRILE IN HUMAN WHOLE BLOOD BY HEADSPACE CAPILLARY GAS CHROMATOGRAPHY WITH CRYOGENIC OVEN TRAPPING</dc:title>
          <dcterms:alternative xml:lang="ja">低温オーブントラッピングキャピラリーガスクロマトグラフィーによるヒト全血中アセトニトリル及びプロピオニトリルの高感度分析</dcterms:alternative>
          <jpcoar:creator>
            <jpcoar:creatorName>Kaneko, Rina</jpcoar:creatorName>
          </jpcoar:creator>
          <jpcoar:creator>
            <jpcoar:creatorName>Fukui, Rena</jpcoar:creatorName>
          </jpcoar:creator>
          <jpcoar:creator>
            <jpcoar:creatorName>Watanabe, Kanako</jpcoar:creatorName>
          </jpcoar:creator>
          <jpcoar:creator>
            <jpcoar:creatorName>Hirata, Yukari</jpcoar:creatorName>
          </jpcoar:creator>
          <jpcoar:creator>
            <jpcoar:creatorName>Hamajima, Makoto</jpcoar:creatorName>
          </jpcoar:creator>
          <jpcoar:creator>
            <jpcoar:creatorName>Ishii, Akira</jpcoar:creatorName>
          </jpcoar:creator>
          <dc:rights xml:lang="ja">Copyright 日本法中毒学会</dc:rights>
          <dc:rights xml:lang="ja">本文データは日本法中毒学会の許諾のもと掲載しています。</dc:rights>
          <jpcoar:subject subjectScheme="Other">Acetonitrile</jpcoar:subject>
          <jpcoar:subject subjectScheme="Other">Propionitrile</jpcoar:subject>
          <jpcoar:subject subjectScheme="Other">Gas chromatography</jpcoar:subject>
          <jpcoar:subject subjectScheme="Other">Cryogenic oven trapping</jpcoar:subject>
          <jpcoar:subject subjectScheme="Other">Flame thermionic detector (FTD)</jpcoar:subject>
          <jpcoar:subject subjectScheme="Other">NPD</jpcoar:subject>
          <datacite:description xml:lang="en" descriptionType="Abstract">We have developed a simple and sensitive method for determining acetonitrile and propionitrile in human whole blood using capillary gas chromatography (GC) with cryogenic oven trapping. After heating 0.5 ml of a whole blood sample containing both nitriles and 0.5 ml of distilled water in a 7-ml vial at 75℃ for 15 min, 5 ml of the headspace vapor was drawn into a 10-ml syringe and injected to GC with a flame thermionic detector. A sharp peak was obtained for acetonitrile at -10℃ of the initial oven temperature. The extraction efficiencies for acetonitrile and propionitrile were 0.27 and 0.40%, respectively. For quantitation of acetonitrile, propionitrile was used as internal standard, and vise versa. The calibration curves for both compounds gave good linearity in the range of 0.2-6 μg/ml whole blood. The detection limits (signal to noise ratio = 3) were 0.05μg/ml for acetonitrile and 0.01μg/ml for propionitrile. The coefficients of intra-day variations were 1.0% at 0.4μg/ml and 1.7% at 2μg/ml for acetonitrile; 7.1% at 0.4μg/m1 and 1.0 % at 2μg/ml for propionitrile. This method can be applicable for determining these nitriles in whole blood samples in acute and chronic intoxication cases.</datacite:description>
          <dc:publisher xml:lang="ja">日本法中毒学会</dc:publisher>
          <datacite:date dateType="Issued">2005-01-31</datacite:date>
          <dc:language>eng</dc:language>
          <dc:type rdf:resource="http://purl.org/coar/resource_type/c_6501">journal article</dc:type>
          <oaire:version rdf:resource="http://purl.org/coar/version/c_970fb48d4fbd8a85">VoR</oaire:version>
          <jpcoar:identifier identifierType="HDL">http://hdl.handle.net/10271/1751</jpcoar:identifier>
          <jpcoar:identifier identifierType="URI">https://hama-med.repo.nii.ac.jp/records/1718</jpcoar:identifier>
          <jpcoar:sourceIdentifier identifierType="ISSN">09159606</jpcoar:sourceIdentifier>
          <jpcoar:sourceTitle xml:lang="ja">法中毒</jpcoar:sourceTitle>
          <jpcoar:sourceTitle xml:lang="en">Japanese journal of forensic toxicology</jpcoar:sourceTitle>
          <jpcoar:volume>23</jpcoar:volume>
          <jpcoar:issue>1</jpcoar:issue>
          <jpcoar:pageStart>37</jpcoar:pageStart>
          <jpcoar:pageEnd>40</jpcoar:pageEnd>
          <jpcoar:file>
            <jpcoar:URI label="FT-23-37.pdf">https://hama-med.repo.nii.ac.jp/record/1718/files/FT-23-37.pdf</jpcoar:URI>
            <jpcoar:mimeType>application/pdf</jpcoar:mimeType>
            <jpcoar:extent>280.2 kB</jpcoar:extent>
            <datacite:date dateType="Available">2018-08-27</datacite:date>
          </jpcoar:file>
        </jpcoar:jpcoar>
      </metadata>
    </record>
  </GetRecord>
</OAI-PMH>
