{"created":"2023-06-20T15:47:09.422843+00:00","id":1699,"links":{},"metadata":{"_buckets":{"deposit":"dd563d16-20cf-4ba3-9ce1-03dbc872f0d8"},"_deposit":{"created_by":4,"id":"1699","owners":[4],"pid":{"revision_id":0,"type":"depid","value":"1699"},"status":"published"},"_oai":{"id":"oai:hama-med.repo.nii.ac.jp:00001699","sets":["1:11"]},"author_link":["3947","3948","3949","3950","3951"],"item_3_alternative_title_1":{"attribute_name":"その他のタイトル","attribute_value_mlt":[{"subitem_alternative_title":"Sensitive quantification of copper using ESR method","subitem_alternative_title_language":"en"}]},"item_3_biblio_info_5":{"attribute_name":"書誌情報","attribute_value_mlt":[{"bibliographicIssueDates":{"bibliographicIssueDate":"2001-05-15","bibliographicIssueDateType":"Issued"},"bibliographicIssueNumber":"2","bibliographicPageEnd":"189","bibliographicPageStart":"188","bibliographicVolumeNumber":"19","bibliographic_titles":[{"bibliographic_title":"法中毒","bibliographic_titleLang":"ja"},{"bibliographic_title":"Japanese journal of forensic toxicology","bibliographic_titleLang":"en"}]}]},"item_3_description_9":{"attribute_name":"抄録","attribute_value_mlt":[{"subitem_description":"Both colorimetric method using bathocuproine and atomic absorption spectrophotometric method require even 2 ml of serum for the quantification of copper. Therefore, much more sensitive but convenient method is needed for the quantification of small amount of copper in polluted water, food, blood and tissues. The application of ESR method is examined in the present work because Cu++ is paramagnetic and can be measured by ESR method. We confirmed the results of the previous report that diethyldithiocarbamate (DDC) reacted with Cu++at pH from 0 to 10. The Cu++-DDC complex could be extracted with most organic solvents at these pHs. We found that the addition of Na2SO4 facilitated the extraction of the complex with 1-butanol. By this method we can quantify copper using 5μl of plasma within 5 min. Cu++-DDCcomplex in butanol is quite stable and is not affected by a few hour's exposure to room light. The peaks remained unchanged for 3 days when it is kept in the dark and the volume of butanol maintained.","subitem_description_language":"en","subitem_description_type":"Abstract"}]},"item_3_publisher_6":{"attribute_name":"出版者","attribute_value_mlt":[{"subitem_publisher":"日本法中毒学会","subitem_publisher_language":"ja"}]},"item_3_rights_7":{"attribute_name":"権利","attribute_value_mlt":[{"subitem_rights":"Copyright 日本法中毒学会","subitem_rights_language":"ja"},{"subitem_rights":"本文データは日本法中毒学会の許諾のもと掲載しています。","subitem_rights_language":"ja"}]},"item_3_source_id_19":{"attribute_name":"ISSN","attribute_value_mlt":[{"subitem_source_identifier":"09159606","subitem_source_identifier_type":"ISSN"}]},"item_3_version_type_32":{"attribute_name":"著者版フラグ","attribute_value_mlt":[{"subitem_version_resource":"http://purl.org/coar/version/c_970fb48d4fbd8a85","subitem_version_type":"VoR"}]},"item_creator":{"attribute_name":"著者","attribute_type":"creator","attribute_value_mlt":[{"creatorNames":[{"creatorName":"南方, かよ子"}],"nameIdentifiers":[{}]},{"creatorNames":[{"creatorName":"野澤, 秀樹"}],"nameIdentifiers":[{}]},{"creatorNames":[{"creatorName":"渡部, 加奈子"}],"nameIdentifiers":[{}]},{"creatorNames":[{"creatorName":"鈴木, 修"}],"nameIdentifiers":[{}]},{"creatorNames":[{"creatorName":"鈴木, 加奈子"}],"nameIdentifiers":[{}]}]},"item_files":{"attribute_name":"ファイル情報","attribute_type":"file","attribute_value_mlt":[{"accessrole":"open_date","date":[{"dateType":"Available","dateValue":"2018-08-27"}],"displaytype":"detail","filename":"FT-19-188.pdf","filesize":[{"value":"106.3 kB"}],"format":"application/pdf","licensetype":"license_note","mimetype":"application/pdf","url":{"label":"FT-19-188.pdf","url":"https://hama-med.repo.nii.ac.jp/record/1699/files/FT-19-188.pdf"},"version_id":"fb542bda-4beb-4d56-8d3c-6488226b7319"}]},"item_language":{"attribute_name":"言語","attribute_value_mlt":[{"subitem_language":"jpn"}]},"item_resource_type":{"attribute_name":"資源タイプ","attribute_value_mlt":[{"resourcetype":"journal article","resourceuri":"http://purl.org/coar/resource_type/c_6501"}]},"item_title":"電子スピン共鳴を用いた銅の微量定量法","item_titles":{"attribute_name":"タイトル","attribute_value_mlt":[{"subitem_title":"電子スピン共鳴を用いた銅の微量定量法","subitem_title_language":"ja"}]},"item_type_id":"3","owner":"4","path":["11"],"pubdate":{"attribute_name":"PubDate","attribute_value":"2013-08-27"},"publish_date":"2013-08-27","publish_status":"0","recid":"1699","relation_version_is_last":true,"title":["電子スピン共鳴を用いた銅の微量定量法"],"weko_creator_id":"4","weko_shared_id":-1},"updated":"2023-08-02T04:00:29.996715+00:00"}