A convenient online desalination tube coupled with mass spectrometry for the direct detection of iodinated contrast media in untreated human spent hemodialysates.

http://hdl.handle.net/10271/0002000202
http://hdl.handle.net/10271/0002000202
7c121c5b-e3af-4194-8fef-edf1e4bce584
名前 / ファイル ライセンス アクション
DT_956ronbun.pdf 論文本文 (1.3 MB)
license.icon
Item type 学位論文 / Thesis or Dissertation(1)
公開日 2024-09-04
タイトル
タイトル A convenient online desalination tube coupled with mass spectrometry for the direct detection of iodinated contrast media in untreated human spent hemodialysates.
言語 en
言語
言語 eng
資源タイプ
資源タイプ識別子 http://purl.org/coar/resource_type/c_db06
資源タイプ doctoral thesis
アクセス権
アクセス権 open access
アクセス権URI http://purl.org/coar/access_right/c_abf2
その他のタイトル
その他のタイトル 便利なオンライン脱塩チューブおよび質量分析を用いた未処理ヒト透析排液からのヨード系造影剤の直接検出
著者 Nabi, Md. Mahamodun

× Nabi, Md. Mahamodun

en Nabi, Md. Mahamodun

Search repository
書誌情報 en : PLOS ONE

巻 17, 号 6, p. e0268751, 発行日 2022-06-06
出版者
出版者 PLOS (Public Library of Science)
権利
言語 en
権利情報 (C) 2022 Nabi et al. This is an open access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited.
抄録
内容記述タイプ Abstract
内容記述 Background
Mass spectrometry (MS) analysis using direct infusion of biological fluids is often problematic due to high salts/buffers. Iodinated contrast media (ICM) are frequently used for diagnostic imaging purposes, sometimes inducing acute kidney injury (AKI) in patients with reduced kidney function. Therefore, detection of ICM in spent hemodialysates is important for AKI patients who require urgent continuous hemodiafiltration (CHDF) because it allows noninvasive assessment of the patient’s treatment. In this study, we used a novel desalination tube before MS to inject the sample directly and detect ICM.
Methods
Firstly, spent hemodialysates of one patient were injected directly into the electrospray ionization (ESI) source equipped with a quadrupole time-of-flight mass spectrometer (Q-TOF MS) coupled to an online desalination tube for the detection of ICM and other metabolites. Thereafter, spent hemodialysates of two patients were injected directly into the ESI source equipped with a triple quadrupole mass spectrometer (TQ-MS) connected to that online desalination tube to confirm the detection of ICM.
Results
We detected iohexol (an ICM) from untreated spent hemodialysates of the patient-administered iohexol for computed tomography using Q-TOF MS. Using MRM profile analysis, we have confirmed the detection of ICM in the untreated spent hemodialysates of the patients administered for coronary angiography before starting CHDF. Using the desalination tube, we observed approximately 178 times higher signal intensity and 8 times improved signal-to-noise ratio for ioversol (an ICM) compared to data obtained without the desalination tube. This system was capable of tracking the changes of ioversol in spent hemodialysates of AKI patients by measuring spent hemodialysates.
Conclusion
The online desalination tube coupled with MS showed the capability of detecting iohexol and ioversol in spent hemodialysates without additional sample preparation or chromatographic separation. This approach also demonstrated the capacity to monitor the ioversol changes in patients’ spent hemodialysates.
言語 en
学位名
学位名 博士(医学)
学位の区分
内容記述 doctoral
学位の分野
内容記述 医学系研究科
学位授与機関
学位授与機関識別子Scheme kakenhi
学位授与機関識別子 13802
学位授与機関名 浜松医科大学
学位授与年月日
学位授与年月日 2023-09-22
学位授与番号
学位授与番号 甲第956号
EISSN
収録物識別子タイプ EISSN
収録物識別子 1932-6203
PubMed番号
識別子タイプ PMID
関連識別子 35666735
出版社DOI
識別子タイプ DOI
関連識別子 https://doi.org/10.1371/journal.pone.0268751
著者版フラグ
出版タイプ VoR
出版タイプResource http://purl.org/coar/version/c_970fb48d4fbd8a85
戻る
0
views
See details
Views

Versions

Ver.1 2024-09-04 06:04:12.955063
Show All versions

Share

Mendeley Twitter Facebook Print Addthis

Cite as

エクスポート

OAI-PMH
  • OAI-PMH JPCOAR 2.0
  • OAI-PMH JPCOAR 1.0
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX

Confirm


Powered by WEKO3


Powered by WEKO3