{"created":"2024-10-11T01:19:23.173783+00:00","id":2000243,"links":{},"metadata":{"_buckets":{"deposit":"f270d662-8776-4fa8-9ff1-c7b4192e3ff1"},"_deposit":{"created_by":4,"id":"2000243","owner":"4","owners":[4],"pid":{"revision_id":0,"type":"depid","value":"2000243"},"status":"published"},"_oai":{"id":"oai:hama-med.repo.nii.ac.jp:02000243","sets":["1:11"]},"author_link":[],"control_number":"2000243","item_3_biblio_info_5":{"attribute_name":"書誌情報","attribute_value_mlt":[{"bibliographicIssueDates":{"bibliographicIssueDate":"2023-10-05","bibliographicIssueDateType":"Issued"},"bibliographicIssueNumber":"1","bibliographicPageStart":"e15616","bibliographicVolumeNumber":"65","bibliographic_titles":[{"bibliographic_title":"Pediatrics International","bibliographic_titleLang":"en"}]}]},"item_3_description_9":{"attribute_name":"抄録","attribute_value_mlt":[{"subitem_description":"Background\nHypoglycemia is a significant problem for all neonates and requires minimally invasive and reliable monitoring. The primary objective of this study is to verify the safety and accuracy of continuous glucose monitoring (CGM) of full-term neonates using Freestyle® Libre, a flash glucose monitoring (FGM) device.\nMethods\nThe study was conducted on twenty neonates. Shortly after birth, we placed the FGM sensor on the outside of the neonates’ thighs. We scanned the CGM values at 60, 120, 180 and 360 min after birth and simultaneously obtained blood glucose values with plantar capillaries by heel puncture. The neonates wore the sensors for up to 6 hours and then they were removed.\nResults\nOut of the 75 data points to be measured, 65 points (86.7%) were obtained by scan. There was no change in the sensor attachment site in 12 of 18 completed cases in this study, but we observed slight induration in 4 cases (22.2%) and slight redness in 1 case (5.5%) at the sensor puncture site. A moderate correlation was observed between the CGM and blood glucose values. The CGM values tended to be low at 120, 180, and 360 min after birth, and tended to be high only at 60 min after birth.\nConclusions\nThe CGM device was safe to wear on the neonate, and the CGM data correlated well with blood glucose levels. There is dissociation between CGM data and blood glucose levels in the acute period soon after birth when the blood glucose levels change rapidly.","subitem_description_language":"en","subitem_description_type":"Abstract"}]},"item_3_publisher_6":{"attribute_name":"出版者","attribute_value_mlt":[{"subitem_publisher":"John Wiley and Sons","subitem_publisher_language":"en"},{"subitem_publisher":"日本小児科学会","subitem_publisher_language":"ja"}]},"item_3_relation_26":{"attribute_name":"PubMed番号","attribute_value_mlt":[{"subitem_relation_type":"isIdenticalTo","subitem_relation_type_id":{"subitem_relation_type_id_text":"37795844","subitem_relation_type_select":"PMID"}}]},"item_3_relation_28":{"attribute_name":"出版社DOI","attribute_value_mlt":[{"subitem_relation_type":"isVersionOf","subitem_relation_type_id":{"subitem_relation_type_id_text":"https://doi.org/10.1111/ped.15616","subitem_relation_type_select":"DOI"}}]},"item_3_rights_7":{"attribute_name":"権利","attribute_value_mlt":[{"subitem_rights":"This is the peer reviewed version of the following article: \"Safety and accuracy of neonatal continuous glucose monitoring\", 65(1), e15616, 2023, which has been published in final form at https://doi.org/10.1111/ped.15616. This article may be used for non-commercial purposes in accordance with Wiley Terms and Conditions for Use of Self-Archived Versions. This article may not be enhanced, enriched or otherwise transformed into a derivative work, without express permission from Wiley or by statutory rights under applicable legislation. Copyright notices must not be removed, obscured or modified. The article must be linked to Wiley’s version of record on Wiley Online Library and any embedding, framing or otherwise making available the article or pages thereof by third parties from platforms, services and websites other than Wiley Online Library must be prohibited.","subitem_rights_language":"en"}]},"item_3_source_id_19":{"attribute_name":"ISSN","attribute_value_mlt":[{"subitem_source_identifier":"1328-8067","subitem_source_identifier_type":"PISSN"}]},"item_3_source_id_20":{"attribute_name":"EISSN","attribute_value_mlt":[{"subitem_source_identifier":"1442-200X","subitem_source_identifier_type":"EISSN"}]},"item_3_source_id_23":{"attribute_name":"NII書誌ID","attribute_value_mlt":[{"subitem_source_identifier":"AA11320483","subitem_source_identifier_type":"NCID"}]},"item_3_version_type_32":{"attribute_name":"著者版フラグ","attribute_value_mlt":[{"subitem_version_resource":"http://purl.org/coar/version/c_ab4af688f83e57aa","subitem_version_type":"AM"}]},"item_access_right":{"attribute_name":"アクセス権","attribute_value_mlt":[{"subitem_access_right":"open access","subitem_access_right_uri":"http://purl.org/coar/access_right/c_abf2"}]},"item_creator":{"attribute_name":"著者","attribute_type":"creator","attribute_value_mlt":[{"creatorNames":[{"creatorName":"Ohishi, Akira","creatorNameLang":"en","creatorNameType":"Personal"}]},{"creatorNames":[{"creatorName":"Ueno, Daizo","creatorNameLang":"en","creatorNameType":"Personal"}]},{"creatorNames":[{"creatorName":"Fujita, Tomoka","creatorNameLang":"en","creatorNameType":"Personal"}]},{"creatorNames":[{"creatorName":"Segawa, Yuki","creatorNameLang":"en","creatorNameType":"Personal"}]},{"creatorNames":[{"creatorName":"Yamamoto, Takuya","creatorNameLang":"en","creatorNameType":"Personal"}]},{"creatorNames":[{"creatorName":"Fujisawa, Yasuko","creatorNameLang":"en","creatorNameType":"Personal"}]},{"creatorNames":[{"creatorName":"Iijima, Shigeo","creatorNameLang":"en","creatorNameType":"Personal"}]}]},"item_files":{"attribute_name":"ファイル情報","attribute_type":"file","attribute_value_mlt":[{"accessrole":"open_access","date":[{"dateType":"Available","dateValue":"2024-10-10"}],"displaytype":"detail","filename":"Pediatr Int-65-e15616.pdf","filesize":[{"value":"1.4 MB"}],"format":"application/pdf","mimetype":"application/pdf","url":{"objectType":"fulltext","url":"https://hama-med.repo.nii.ac.jp/record/2000243/files/Pediatr Int-65-e15616.pdf"},"version_id":"709aeeab-0a30-48eb-8067-8bca8c7dfb91"},{"accessrole":"open_access","date":[{"dateType":"Available","dateValue":"2024-10-10"}],"displaytype":"detail","filename":"Pediatr Int-65-e15616_Fig.pdf","filesize":[{"value":"897 KB"}],"format":"application/pdf","mimetype":"application/pdf","url":{"objectType":"dataset","url":"https://hama-med.repo.nii.ac.jp/record/2000243/files/Pediatr Int-65-e15616_Fig.pdf"},"version_id":"ce410664-4e82-454a-b262-af36c7dbbe0b"}]},"item_keyword":{"attribute_name":"キーワード","attribute_value_mlt":[{"subitem_subject":"Accuracy","subitem_subject_language":"en","subitem_subject_scheme":"Other"},{"subitem_subject":"Blood glucose","subitem_subject_language":"en","subitem_subject_scheme":"Other"},{"subitem_subject":"Neonate","subitem_subject_language":"en","subitem_subject_scheme":"Other"},{"subitem_subject":"Safety","subitem_subject_language":"en","subitem_subject_scheme":"Other"},{"subitem_subject":"Continuous glucose monitoring","subitem_subject_language":"en","subitem_subject_scheme":"Other"}]},"item_language":{"attribute_name":"言語","attribute_value_mlt":[{"subitem_language":"eng"}]},"item_resource_type":{"attribute_name":"資源タイプ","attribute_value_mlt":[{"resourcetype":"journal article","resourceuri":"http://purl.org/coar/resource_type/c_6501"}]},"item_title":"Safety and accuracy of neonatal continuous glucose monitoring","item_titles":{"attribute_name":"タイトル","attribute_value_mlt":[{"subitem_title":"Safety and accuracy of neonatal continuous glucose monitoring","subitem_title_language":"en"}]},"item_type_id":"3","owner":"4","path":["11"],"pubdate":{"attribute_name":"PubDate","attribute_value":"2024-11-11"},"publish_date":"2024-11-11","publish_status":"0","recid":"2000243","relation_version_is_last":true,"title":["Safety and accuracy of neonatal continuous glucose monitoring"],"weko_creator_id":"4","weko_shared_id":-1},"updated":"2025-01-09T07:54:30.879089+00:00"}