{"created":"2025-02-17T02:49:42.518108+00:00","id":2000343,"links":{},"metadata":{"_buckets":{"deposit":"21086f04-7319-4095-aa92-b191c4dd84a7"},"_deposit":{"created_by":4,"id":"2000343","owner":"4","owners":[4],"pid":{"revision_id":0,"type":"depid","value":"2000343"},"status":"published"},"_oai":{"id":"oai:hama-med.repo.nii.ac.jp:02000343","sets":["1:11"]},"author_link":[],"control_number":"2000343","item_3_biblio_info_5":{"attribute_name":"bibliographic_information","attribute_value_mlt":[{"bibliographicIssueDates":{"bibliographicIssueDate":"2024-07-05","bibliographicIssueDateType":"Issued"},"bibliographicIssueNumber":"7","bibliographicPageEnd":"940","bibliographicPageStart":"938","bibliographicVolumeNumber":"47","bibliographic_titles":[{"bibliographic_title":"Pacing and Clinical Electrophysiology (PACE)","bibliographic_titleLang":"en"}]}]},"item_3_description_9":{"attribute_name":"抄録","attribute_value_mlt":[{"subitem_description":"The procedural success in the implantation of cardiac electric devices depends on both the implanted position and the electric performance. The capture threshold and the pacing output affect the estimated battery longevity. In a case with a high capture threshold, recapture and reimplantation of a leadless pacemaker are commonly recommended. We experienced a case with the rate-dependent elevation of the capture threshold following the implantation of a leadless pacemaker. The recognition of the rate-dependency of the capture threshold and the acceptable programming could avoid the unnecessary recapture and reimplantation of that, avoiding the increase of procedural risks.","subitem_description_language":"en","subitem_description_type":"Abstract"}]},"item_3_publisher_6":{"attribute_name":"出版者","attribute_value_mlt":[{"subitem_publisher":"John Wiley and Sons","subitem_publisher_language":"en"}]},"item_3_relation_26":{"attribute_name":"item_3_relation_26","attribute_value_mlt":[{"subitem_relation_type":"isVersionOf","subitem_relation_type_id":{"subitem_relation_type_id_text":"38010832","subitem_relation_type_select":"PMID"}}]},"item_3_relation_28":{"attribute_name":"item_3_relation_28","attribute_value_mlt":[{"subitem_relation_type":"isVersionOf","subitem_relation_type_id":{"subitem_relation_type_id_text":"https://doi.org/10.1111/pace.14884","subitem_relation_type_select":"DOI"}}]},"item_3_rights_7":{"attribute_name":"権利","attribute_value_mlt":[{"subitem_rights":"This is the peer reviewed version of the following article: \"Rate-dependent elevation of the capture threshold after implantation of a leadless pacemaker\", 47(7), pp938-940, c2023, which has been published in final form at https://doi.org/10.1111/pace.14884. This article may be used for non-commercial purposes in accordance with Wiley Terms and Conditions for Use of Self-Archived Versions. This article may not be enhanced, enriched or otherwise transformed into a derivative work, without express permission from Wiley or by statutory rights under applicable legislation. Copyright notices must not be removed, obscured or modified. The article must be linked to Wiley’s version of record on Wiley Online Library and any embedding, framing or otherwise making available the article or pages thereof by third parties from platforms, services and websites other than Wiley Online Library must be prohibited.","subitem_rights_language":"en"}]},"item_3_source_id_19":{"attribute_name":"ISSN","attribute_value_mlt":[{"subitem_source_identifier":"0147-8389","subitem_source_identifier_type":"PISSN"}]},"item_3_source_id_20":{"attribute_name":"EISSN","attribute_value_mlt":[{"subitem_source_identifier":"1540-8159","subitem_source_identifier_type":"EISSN"}]},"item_3_source_id_23":{"attribute_name":"item_3_source_id_23","attribute_value_mlt":[{"subitem_source_identifier":"AA00766720","subitem_source_identifier_type":"NCID"}]},"item_3_version_type_32":{"attribute_name":"出版タイプ","attribute_value_mlt":[{"subitem_version_resource":"http://purl.org/coar/version/c_ab4af688f83e57aa","subitem_version_type":"AM"}]},"item_access_right":{"attribute_name":"アクセス権","attribute_value_mlt":[{"subitem_access_right":"open access","subitem_access_right_uri":"http://purl.org/coar/access_right/c_abf2"}]},"item_creator":{"attribute_name":"著者","attribute_type":"creator","attribute_value_mlt":[{"creatorNames":[{"creatorName":"Sano, Makoto","creatorNameLang":"en","creatorNameType":"Personal"}]},{"creatorNames":[{"creatorName":"Takahashi, Naoyuki","creatorNameLang":"en","creatorNameType":"Personal"}]},{"creatorNames":[{"creatorName":"Kaneko, Yutaro","creatorNameLang":"en","creatorNameType":"Personal"}]},{"creatorNames":[{"creatorName":"Narumi, Taro","creatorNameLang":"en","creatorNameType":"Personal"}]},{"creatorNames":[{"creatorName":"Naruse, Yoshihisa","creatorNameLang":"en","creatorNameType":"Personal"}]},{"creatorNames":[{"creatorName":"Maekawa, Yuichiro","creatorNameLang":"en","creatorNameType":"Personal"}]}]},"item_files":{"attribute_name":"ファイル情報","attribute_type":"file","attribute_value_mlt":[{"accessrole":"open_access","date":[{"dateType":"Available","dateValue":"2025-02-17"}],"displaytype":"detail","filename":"PACE-47-938.pdf","filesize":[{"value":"4.9 MB"}],"format":"application/pdf","mimetype":"application/pdf","url":{"objectType":"fulltext","url":"https://hama-med.repo.nii.ac.jp/record/2000343/files/PACE-47-938.pdf"},"version_id":"d5445ffb-ecce-4e71-9d3c-a0bfcebc033a"}]},"item_keyword":{"attribute_name":"キーワード","attribute_value_mlt":[{"subitem_subject":"capture threshold","subitem_subject_language":"en","subitem_subject_scheme":"Other"},{"subitem_subject":"leadless pacemaker","subitem_subject_language":"en","subitem_subject_scheme":"Other"},{"subitem_subject":"phase 4 block","subitem_subject_language":"en","subitem_subject_scheme":"Other"}]},"item_language":{"attribute_name":"言語","attribute_value_mlt":[{"subitem_language":"eng"}]},"item_resource_type":{"attribute_name":"item_resource_type","attribute_value_mlt":[{"resourcetype":"journal article","resourceuri":"http://purl.org/coar/resource_type/c_6501"}]},"item_title":"Rate-dependent elevation of the capture threshold after implantation of a leadless pacemaker","item_titles":{"attribute_name":"タイトル","attribute_value_mlt":[{"subitem_title":"Rate-dependent elevation of the capture threshold after implantation of a leadless pacemaker","subitem_title_language":"en"}]},"item_type_id":"3","owner":"4","path":["11"],"pubdate":{"attribute_name":"PubDate","attribute_value":"2025-02-26"},"publish_date":"2025-02-26","publish_status":"0","recid":"2000343","relation_version_is_last":true,"title":["Rate-dependent elevation of the capture threshold after implantation of a leadless pacemaker"],"weko_creator_id":"4","weko_shared_id":-1},"updated":"2025-02-26T06:42:44.751038+00:00"}