{"created":"2023-06-20T15:47:30.811468+00:00","id":2051,"links":{},"metadata":{"_buckets":{"deposit":"0823ec88-45fd-424b-86de-4571772c4a53"},"_deposit":{"created_by":4,"id":"2051","owners":[4],"pid":{"revision_id":0,"type":"depid","value":"2051"},"status":"published"},"_oai":{"id":"oai:hama-med.repo.nii.ac.jp:00002051","sets":["1:11"]},"author_link":["5399"],"item_3_biblio_info_5":{"attribute_name":"書誌情報","attribute_value_mlt":[{"bibliographicIssueDates":{"bibliographicIssueDate":"1992-09-15","bibliographicIssueDateType":"Issued"},"bibliographicIssueNumber":"6","bibliographicPageEnd":"633","bibliographicPageStart":"628","bibliographicVolumeNumber":"6","bibliographic_titles":[{"bibliographic_title":"日本呼吸器外科学会雑誌","bibliographic_titleLang":"ja"}]}]},"item_3_description_9":{"attribute_name":"抄録","attribute_value_mlt":[{"subitem_description":"術後の横隔膜機能と経横隔膜中心静脈圧の関連性について, 動物実験にて検討した. 雑種成犬を用い全麻・自発呼吸下に上腹部正中切開で開腹した.全麻・自発呼吸 (室内気) 下における手術前後の食道内圧 (Pes), 胃内圧 (Pga), 上大静脈圧 (PSVC), 下大静脈圧 (PIVC) を測定し, 各圧の呼吸による変化 (ΔP) から経横隔膜消化管圧の変化ΔPdi (=ΔPga-ΔPes) と経横隔膜中心静脈圧の変化ΔP'di (=ΔPIVC-ΔPsvc) およびΔPga/ΔPdiとΔPIVC/ΔP'diを求め比較した. ΔPdi, ΔP'di共有意に低下し (p<0.01, p<0.05), 各々の変化率は, -37.25±20.17%と一23.25±10.30%で有意な相関を示した (r=0.85, p<0.01).ΔPga/ΔPdi, ΔPIVC/ΔP'diは共に有意な変化は無かった. 経横隔膜中心静脈圧を術後横隔膜機能の連続モニターの指標として臨床応用する可能性が示された.","subitem_description_language":"ja","subitem_description_type":"Abstract"}]},"item_3_publisher_6":{"attribute_name":"出版者","attribute_value_mlt":[{"subitem_publisher":"日本呼吸器外科学会","subitem_publisher_language":"ja"}]},"item_3_relation_28":{"attribute_name":"出版社DOI","attribute_value_mlt":[{"subitem_relation_type":"isIdenticalTo","subitem_relation_type_id":{"subitem_relation_type_id_text":"10.2995/jacsurg.6.628","subitem_relation_type_select":"DOI"}}]},"item_3_rights_7":{"attribute_name":"権利","attribute_value_mlt":[{"subitem_rights":"Copyright 日本呼吸器外科学会","subitem_rights_language":"ja"},{"subitem_rights":"本文データは学協会の許諾に基づきJournal archiveから複製したものである","subitem_rights_language":"ja"}]},"item_3_source_id_19":{"attribute_name":"ISSN","attribute_value_mlt":[{"subitem_source_identifier":"09190945","subitem_source_identifier_type":"ISSN"}]},"item_3_source_id_20":{"attribute_name":"EISSN","attribute_value_mlt":[{"subitem_source_identifier":"18814158","subitem_source_identifier_type":"ISSN"}]},"item_3_version_type_32":{"attribute_name":"著者版フラグ","attribute_value_mlt":[{"subitem_version_resource":"http://purl.org/coar/version/c_970fb48d4fbd8a85","subitem_version_type":"VoR"}]},"item_creator":{"attribute_name":"著者","attribute_type":"creator","attribute_value_mlt":[{"creatorNames":[{"creatorName":"野木村, 宏","creatorNameLang":"ja"}],"nameIdentifiers":[{"nameIdentifier":"5399","nameIdentifierScheme":"WEKO"}]}]},"item_files":{"attribute_name":"ファイル情報","attribute_type":"file","attribute_value_mlt":[{"accessrole":"open_date","date":[{"dateType":"Available","dateValue":"2018-08-27"}],"displaytype":"detail","filename":"Kokyu6-628.pdf","filesize":[{"value":"798.1 kB"}],"format":"application/pdf","licensetype":"license_note","mimetype":"application/pdf","url":{"label":"Kokyu6-628.pdf","url":"https://hama-med.repo.nii.ac.jp/record/2051/files/Kokyu6-628.pdf"},"version_id":"da5aa8e3-28cf-410c-871b-30370e9a9104"}]},"item_keyword":{"attribute_name":"キーワード","attribute_value_mlt":[{"subitem_subject":"呼吸筋","subitem_subject_language":"ja","subitem_subject_scheme":"Other"},{"subitem_subject":"横隔膜機能","subitem_subject_language":"ja","subitem_subject_scheme":"Other"},{"subitem_subject":"経横隔膜圧","subitem_subject_language":"ja","subitem_subject_scheme":"Other"},{"subitem_subject":"中心静脈圧","subitem_subject_language":"ja","subitem_subject_scheme":"Other"}]},"item_language":{"attribute_name":"言語","attribute_value_mlt":[{"subitem_language":"jpn"}]},"item_resource_type":{"attribute_name":"資源タイプ","attribute_value_mlt":[{"resourcetype":"journal article","resourceuri":"http://purl.org/coar/resource_type/c_6501"}]},"item_title":"経横隔膜中心静脈圧による術後横隔膜機能モニターの実験的試み","item_titles":{"attribute_name":"タイトル","attribute_value_mlt":[{"subitem_title":"経横隔膜中心静脈圧による術後横隔膜機能モニターの実験的試み","subitem_title_language":"ja"}]},"item_type_id":"3","owner":"4","path":["11"],"pubdate":{"attribute_name":"PubDate","attribute_value":"2013-08-27"},"publish_date":"2013-08-27","publish_status":"0","recid":"2051","relation_version_is_last":true,"title":["経横隔膜中心静脈圧による術後横隔膜機能モニターの実験的試み"],"weko_creator_id":"4","weko_shared_id":-1},"updated":"2023-08-02T07:29:08.923623+00:00"}