{"created":"2023-06-20T15:47:47.641559+00:00","id":2330,"links":{},"metadata":{"_buckets":{"deposit":"d37e6cec-eead-4a6c-85fa-32d164fb175f"},"_deposit":{"created_by":4,"id":"2330","owners":[4],"pid":{"revision_id":0,"type":"depid","value":"2330"},"status":"published"},"_oai":{"id":"oai:hama-med.repo.nii.ac.jp:00002330","sets":["1:11"]},"author_link":[],"item_3_biblio_info_5":{"attribute_name":"書誌情報","attribute_value_mlt":[{"bibliographicIssueDates":{"bibliographicIssueDate":"1986-07-01","bibliographicIssueDateType":"Issued"},"bibliographicIssueNumber":"3","bibliographicPageEnd":"292","bibliographicPageStart":"279","bibliographicVolumeNumber":"35","bibliographic_titles":[{"bibliographic_title":"Experimental Animals"}]}]},"item_3_description_9":{"attribute_name":"抄録","attribute_value_mlt":[{"subitem_description":"微生物の感染に起因する抗体をコンピューター解析を導入したELISA法で定量することによって, 新しい診断法を確立した。マウスSendai virus自然感染例での診断を実施したところ, 多数の検体処理が迅速に, より精度の高いものとして可能となった。Sendai virusに対するマウスのIgGとIgM抗体の定量はstandard purified mouse IgGまたはIgMの定量曲線に照して検体が示したO.D.値から算出された。この操作はすべてTitertek Multiskan MCに直結したマイクロコンピューター (Micro 8) で行われた。測定限界低値はIgGで10ng/ml, IgMで30ng/mlであった。Sendai virus抗体陽性と判定された91検体のうち45検体がIgGとIgM抗体陽性, 44検体がIgG抗体のみ, 2検体がIgM抗体のみ陽性で, 抗体価はIgGが1: 10〜1: 12, 800, IgMが1: 20〜1: 160であった。この抗体価での抗体量はIgGで0.1〜154μg/ml, IgMで0.5〜4.8μg/mlと判読された。抗体価と抗体量の間には相関関係が認められ, IgG量が約10μg/mlと判読された時は1: 400, 30μg/mlの時は1: 1, 600, IgM量が約2.4μg/mlの時は1: 80, 4μg/mlの時は1: 160の抗体価と判定された。","subitem_description_type":"Abstract"}]},"item_3_publisher_6":{"attribute_name":"出版者","attribute_value_mlt":[{"subitem_publisher":"日本実験動物学会"}]},"item_3_relation_28":{"attribute_name":"出版社DOI","attribute_value_mlt":[{"subitem_relation_type":"isIdenticalTo","subitem_relation_type_id":{"subitem_relation_type_id_text":"10.1538/expanim1978.35.3_279","subitem_relation_type_select":"DOI"}}]},"item_3_rights_7":{"attribute_name":"権利","attribute_value_mlt":[{"subitem_rights":"Copyright 日本実験動物学会"}]},"item_3_source_id_19":{"attribute_name":"ISSN","attribute_value_mlt":[{"subitem_source_identifier":"00075124","subitem_source_identifier_type":"ISSN"}]},"item_3_source_id_20":{"attribute_name":"EISSN","attribute_value_mlt":[{"subitem_source_identifier":"18817122","subitem_source_identifier_type":"ISSN"}]},"item_3_version_type_32":{"attribute_name":"著者版フラグ","attribute_value_mlt":[{"subitem_version_resource":"http://purl.org/coar/version/c_970fb48d4fbd8a85","subitem_version_type":"VoR"}]},"item_creator":{"attribute_name":"著者","attribute_type":"creator","attribute_value_mlt":[{"creatorNames":[{"creatorName":"矢鍋, 誠"}]},{"creatorNames":[{"creatorName":"吉田, 孝人"}]}]},"item_files":{"attribute_name":"ファイル情報","attribute_type":"file","attribute_value_mlt":[{"accessrole":"open_date","date":[{"dateType":"Available","dateValue":"2018-08-27"}],"displaytype":"detail","filename":"ExpAnim35_3-279.pdf","filesize":[{"value":"1.3 MB"}],"format":"application/pdf","licensetype":"license_note","mimetype":"application/pdf","url":{"label":"ExpAnim35_3-279.pdf","url":"https://hama-med.repo.nii.ac.jp/record/2330/files/ExpAnim35_3-279.pdf"},"version_id":"7b6dbf97-2b01-41b0-a719-8802476cd8f9"}]},"item_language":{"attribute_name":"言語","attribute_value_mlt":[{"subitem_language":"jpn"}]},"item_resource_type":{"attribute_name":"資源タイプ","attribute_value_mlt":[{"resourcetype":"journal article","resourceuri":"http://purl.org/coar/resource_type/c_6501"}]},"item_title":"マイクロコンピューターを導入したELISA法での免疫グロブリン定量によるマウス感染症の診断","item_titles":{"attribute_name":"タイトル","attribute_value_mlt":[{"subitem_title":"マイクロコンピューターを導入したELISA法での免疫グロブリン定量によるマウス感染症の診断","subitem_title_language":"ja"}]},"item_type_id":"3","owner":"4","path":["11"],"pubdate":{"attribute_name":"PubDate","attribute_value":"2013-08-27"},"publish_date":"2013-08-27","publish_status":"0","recid":"2330","relation_version_is_last":true,"title":["マイクロコンピューターを導入したELISA法での免疫グロブリン定量によるマウス感染症の診断"],"weko_creator_id":"4","weko_shared_id":-1},"updated":"2023-08-02T04:53:00.935005+00:00"}