{"created":"2023-06-20T15:47:50.505109+00:00","id":2371,"links":{},"metadata":{"_buckets":{"deposit":"2912a6ca-1a1e-432e-9445-d74e617a54c4"},"_deposit":{"created_by":4,"id":"2371","owners":[4],"pid":{"revision_id":0,"type":"depid","value":"2371"},"status":"published"},"_oai":{"id":"oai:hama-med.repo.nii.ac.jp:00002371","sets":["1:11"]},"author_link":[],"item_3_biblio_info_5":{"attribute_name":"書誌情報","attribute_value_mlt":[{"bibliographicIssueDates":{"bibliographicIssueDate":"1979-12-30","bibliographicIssueDateType":"Issued"},"bibliographicIssueNumber":"4","bibliographicPageEnd":"546","bibliographicPageStart":"541","bibliographicVolumeNumber":"10","bibliographic_titles":[{"bibliographic_title":"臨床薬理"}]}]},"item_3_description_9":{"attribute_name":"抄録","attribute_value_mlt":[{"subitem_description":"An automatic continuous systolic blood pressure monitor (Shimazu SCS-501) and a deep body thermometer (Terumo finer core temp DC-1) were used to observe hemodynamic changes induced by thymoxamine hydrochloride, FK 749, and hemodialysis. Three actue hypotension cases were observed in these studies. By means of SCS-501, DC-1, and a sphygmomanometer, it was suggested that the acute hypotension cases differed from each other. From these observations the authors concluded that the combined use of SCS-501 and DC-1 with an ordinary sphygmomanometer gives them detailed information about hemodynamic changes and that both pieces of equipment will be very useful in estimating the safety and effects of drugs.","subitem_description_type":"Abstract"}]},"item_3_publisher_6":{"attribute_name":"出版者","attribute_value_mlt":[{"subitem_publisher":"日本臨床薬理学会"}]},"item_3_rights_7":{"attribute_name":"権利","attribute_value_mlt":[{"subitem_rights":"Copyright 日本臨床薬理学会"}]},"item_3_source_id_19":{"attribute_name":"ISSN","attribute_value_mlt":[{"subitem_source_identifier":"03881601","subitem_source_identifier_type":"ISSN"}]},"item_3_source_id_20":{"attribute_name":"EISSN","attribute_value_mlt":[{"subitem_source_identifier":"18828272","subitem_source_identifier_type":"ISSN"}]},"item_3_version_type_32":{"attribute_name":"著者版フラグ","attribute_value_mlt":[{"subitem_version_resource":"http://purl.org/coar/version/c_970fb48d4fbd8a85","subitem_version_type":"VoR"}]},"item_creator":{"attribute_name":"著者","attribute_type":"creator","attribute_value_mlt":[{"creatorNames":[{"creatorName":"Nakashima, Mitsuyoshi"}]},{"creatorNames":[{"creatorName":"Suzuki, Kunifumi"}]},{"creatorNames":[{"creatorName":"Hashimoto, Hisakuni"}]},{"creatorNames":[{"creatorName":"Kanamaru, Mitsutaka"}]}]},"item_files":{"attribute_name":"ファイル情報","attribute_type":"file","attribute_value_mlt":[{"accessrole":"open_date","date":[{"dateType":"Available","dateValue":"2018-08-27"}],"displaytype":"detail","filename":"JJClinPharTher10_4-541.pdf","filesize":[{"value":"588.4 kB"}],"format":"application/pdf","licensetype":"license_note","mimetype":"application/pdf","url":{"label":"JJClinPharTher10_4-541.pdf","url":"https://hama-med.repo.nii.ac.jp/record/2371/files/JJClinPharTher10_4-541.pdf"},"version_id":"a67e607f-9211-4879-8d97-83d88f5d881f"}]},"item_keyword":{"attribute_name":"キーワード","attribute_value_mlt":[{"subitem_subject":"New equipments in clinical trials","subitem_subject_scheme":"Other"},{"subitem_subject":"Noninvasive methods","subitem_subject_scheme":"Other"},{"subitem_subject":"Analysis of acute hypotension cases","subitem_subject_scheme":"Other"}]},"item_language":{"attribute_name":"言語","attribute_value_mlt":[{"subitem_language":"eng"}]},"item_resource_type":{"attribute_name":"資源タイプ","attribute_value_mlt":[{"resourcetype":"journal article","resourceuri":"http://purl.org/coar/resource_type/c_6501"}]},"item_title":"Evaluation of a Noninvasive Automatic Continuous Systolic Blood Pressure Monitor and a Noninvasive Deep Body Ther mometer for Clinical Trials Comparison of Three Acute Hypotension Cases","item_titles":{"attribute_name":"タイトル","attribute_value_mlt":[{"subitem_title":"Evaluation of a Noninvasive Automatic Continuous Systolic Blood Pressure Monitor and a Noninvasive Deep Body Ther mometer for Clinical Trials Comparison of Three Acute Hypotension Cases","subitem_title_language":"en"}]},"item_type_id":"3","owner":"4","path":["11"],"pubdate":{"attribute_name":"PubDate","attribute_value":"2013-08-27"},"publish_date":"2013-08-27","publish_status":"0","recid":"2371","relation_version_is_last":true,"title":["Evaluation of a Noninvasive Automatic Continuous Systolic Blood Pressure Monitor and a Noninvasive Deep Body Ther mometer for Clinical Trials Comparison of Three Acute Hypotension Cases"],"weko_creator_id":"4","weko_shared_id":-1},"updated":"2023-08-02T04:59:55.380541+00:00"}