{"created":"2023-06-20T15:48:53.960654+00:00","id":3434,"links":{},"metadata":{"_buckets":{"deposit":"fa7de306-94c6-42fa-ac11-7593d5194f30"},"_deposit":{"created_by":4,"id":"3434","owners":[4],"pid":{"revision_id":0,"type":"depid","value":"3434"},"status":"published"},"_oai":{"id":"oai:hama-med.repo.nii.ac.jp:00003434","sets":["2:15:17"]},"author_link":["10003"],"item_5_alternative_title_1":{"attribute_name":"その他のタイトル","attribute_value_mlt":[{"subitem_alternative_title":"唾液微弱化学発光測定法を用いたストレス測定の有効性","subitem_alternative_title_language":"ja"}]},"item_5_biblio_info_5":{"attribute_name":"書誌情報","attribute_value_mlt":[{"bibliographicIssueDates":{"bibliographicIssueDate":"2019","bibliographicIssueDateType":"Issued"},"bibliographicIssueNumber":"4","bibliographicPageEnd":"337","bibliographicPageStart":"330","bibliographicVolumeNumber":"67","bibliographic_titles":[{"bibliographic_title":"日本職業・災害医学会会誌","bibliographic_titleLang":"ja"},{"bibliographic_title":"Japanese Journal of Occupational Medicine and Traumatology","bibliographic_titleLang":"en"}]}]},"item_5_date_granted_17":{"attribute_name":"学位授与年月日","attribute_value_mlt":[{"subitem_dategranted":"2019-03-08"}]},"item_5_degree_grantor_15":{"attribute_name":"学位授与機関","attribute_value_mlt":[{"subitem_degreegrantor":[{"subitem_degreegrantor_language":"ja","subitem_degreegrantor_name":"浜松医科大学"}],"subitem_degreegrantor_identifier":[{"subitem_degreegrantor_identifier_name":"13802","subitem_degreegrantor_identifier_scheme":"kakenhi"}]}]},"item_5_degree_name_12":{"attribute_name":"学位名","attribute_value_mlt":[{"subitem_degreename":"博士(医学)","subitem_degreename_language":"ja"}]},"item_5_description_13":{"attribute_name":"学位の区分","attribute_value_mlt":[{"subitem_description":"doctoral","subitem_description_language":"en","subitem_description_type":"Other"}]},"item_5_description_14":{"attribute_name":"学位の分野","attribute_value_mlt":[{"subitem_description":"医学系研究科","subitem_description_language":"ja","subitem_description_type":"Other"}]},"item_5_description_9":{"attribute_name":"抄録","attribute_value_mlt":[{"subitem_description":"The incidence of stress-induced psychiatric disorders has increased rapidly in recent years. Screening for stress markers enables early detection and treatment of conditions in which stress responses affect health. Salivary ultra-weak chemiluminescence (UCL) can detect peroxidase and thiocyanate ions, which are secreted and increased in saliva under stress. Forty-four patients with diabetes mellitus who were admitted for diabetic education because of their high prevalence of depression and 14 healthy hospital staff members were included. Level variations of stress-related substances in saliva were measured by UCL. Simultaneously, salivary levels of cortisol and chromograninA (CgA) were measured, and the short form of the Profile of Mood States questionnaire was administered. Chemiluminescence intensity correlated with increases in depression-dejection subscale scores, and had a positive and negative correlation with CgA and cortisol levels, respectively. The hospital staff and patients differed significantly in chemiluminescence intensities, cortisol levels, and depression-dejection scores. In conclusion, UCL intensity was correlated with depression scores and levels of classical stress markers, with significant differences between hospital staff and patients. UCL intensity may thus allow the measurement of increases in psychological stress. Furthermore, because saliva absorbed by filter paper can be used, samples can easily be collected and analyzed.","subitem_description_language":"en","subitem_description_type":"Abstract"}]},"item_5_dissertation_number_18":{"attribute_name":"学位授与番号","attribute_value_mlt":[{"subitem_dissertationnumber":"甲第793号"}]},"item_5_publisher_6":{"attribute_name":"出版者","attribute_value_mlt":[{"subitem_publisher":"日本職業・災害医学会","subitem_publisher_language":"ja"},{"subitem_publisher":"Japanese society of Occupational Medicine and Traumatology","subitem_publisher_language":"en"}]},"item_5_relation_27":{"attribute_name":"医中誌論文ID","attribute_value_mlt":[{"subitem_relation_type_id":{"subitem_relation_type_id_text":"2020090816","subitem_relation_type_select":"ICHUSHI"}}]},"item_5_source_id_19":{"attribute_name":"ISSN","attribute_value_mlt":[{"subitem_source_identifier":"1345-2592","subitem_source_identifier_type":"PISSN"}]},"item_5_version_type_32":{"attribute_name":"著者版フラグ","attribute_value_mlt":[{"subitem_version_resource":"http://purl.org/coar/version/c_ab4af688f83e57aa","subitem_version_type":"AM"}]},"item_access_right":{"attribute_name":"アクセス権","attribute_value_mlt":[{"subitem_access_right":"open access","subitem_access_right_uri":"http://purl.org/coar/access_right/c_abf2"}]},"item_creator":{"attribute_name":"著者","attribute_type":"creator","attribute_value_mlt":[{"creatorNames":[{"creatorName":"中村, 正光","creatorNameLang":"ja"}],"nameIdentifiers":[{}]}]},"item_files":{"attribute_name":"ファイル情報","attribute_type":"file","attribute_value_mlt":[{"accessrole":"open_date","date":[{"dateType":"Available","dateValue":"2019-07-22"}],"displaytype":"detail","filename":"DT_793ronbun.pdf","filesize":[{"value":"388.9 kB"}],"format":"application/pdf","licensetype":"license_note","mimetype":"application/pdf","url":{"label":"論文本文","objectType":"fulltext","url":"https://hama-med.repo.nii.ac.jp/record/3434/files/DT_793ronbun.pdf"},"version_id":"5c90b9ae-d071-4da7-bb98-3898a2d4031b"}]},"item_keyword":{"attribute_name":"キーワード","attribute_value_mlt":[{"subitem_subject":"ultra-weak chemiluminescence","subitem_subject_language":"en","subitem_subject_scheme":"Other"},{"subitem_subject":"Profile of Mood States","subitem_subject_language":"en","subitem_subject_scheme":"Other"},{"subitem_subject":"stress marker","subitem_subject_language":"en","subitem_subject_scheme":"Other"}]},"item_language":{"attribute_name":"言語","attribute_value_mlt":[{"subitem_language":"eng"}]},"item_resource_type":{"attribute_name":"資源タイプ","attribute_value_mlt":[{"resourcetype":"doctoral thesis","resourceuri":"http://purl.org/coar/resource_type/c_db06"}]},"item_title":"Efficacy of stress measurements using salivary ultra-weak chemiluminescence","item_titles":{"attribute_name":"タイトル","attribute_value_mlt":[{"subitem_title":"Efficacy of stress measurements using salivary ultra-weak chemiluminescence","subitem_title_language":"en"}]},"item_type_id":"5","owner":"4","path":["17"],"pubdate":{"attribute_name":"PubDate","attribute_value":"2019-07-22"},"publish_date":"2019-07-22","publish_status":"0","recid":"3434","relation_version_is_last":true,"title":["Efficacy of stress measurements using salivary ultra-weak chemiluminescence"],"weko_creator_id":"4","weko_shared_id":-1},"updated":"2023-10-17T07:16:47.169058+00:00"}