{"_buckets": {"deposit": "3549544b-8866-4994-a352-383867e9c47f"}, "_deposit": {"created_by": 4, "id": "3822", "owners": [4], "pid": {"revision_id": 0, "type": "depid", "value": "3822"}, "status": "published"}, "_oai": {"id": "oai:hama-med.repo.nii.ac.jp:00003822", "sets": ["11"]}, "author_link": ["11410", "11409", "11408", "11411"], "item_3_biblio_info_5": {"attribute_name": "書誌情報", "attribute_value_mlt": [{"bibliographicIssueDates": {"bibliographicIssueDate": "2021-08", "bibliographicIssueDateType": "Issued"}, "bibliographicIssueNumber": "2", "bibliographicPageEnd": "422", "bibliographicPageStart": "420", "bibliographicVolumeNumber": "60", "bibliographic_titles": [{"bibliographic_title": "European Journal of Cardio-Thoracic Surgery"}]}]}, "item_3_description_30": {"attribute_name": "フォーマット", "attribute_value_mlt": [{"subitem_description": "application/pdf", "subitem_description_type": "Other"}]}, "item_3_description_9": {"attribute_name": "抄録", "attribute_value_mlt": [{"subitem_description": "To prevent embolic stroke during thoracic endovascular aortic repair, we have adopted the brain isolation technique since June 2014 in nine selected high risk patients (9/134: 6.7%) having ulcerated or protruding atheromas within the proximal aorta. Cardiopulmonary bypass was used to prevent aortic atheromas from entering the brain. We used a heparin-coated closed-loop cardiopulmonary bypass system incorporating a soft reservoir bag with 1 mg/kg heparin to minimize the disadvantages of extracorporeal circulation. The bypass graft (right axillary-left carotid-left axillary) was used as an arterial inflow in patients undergoing zone-1 landing (n=8), while peripheral cannulation into three brachiocephalic arteries was employed in the remaining patient. Initial pump flow was set at 1.3 L/min/m2, and native cardiac output was reduced by adjusting the reservoir bag volume. Aortography was performed to confirm non-visualization of the arch vessels before catheter manipulation. There was no mortality and one solitary left cerebellar infarction.", "subitem_description_type": "Abstract"}]}, "item_3_publisher_6": {"attribute_name": "出版者", "attribute_value_mlt": [{"subitem_publisher": "Oxford University Press"}]}, "item_3_relation_26": {"attribute_name": "PubMed番号", "attribute_value_mlt": [{"subitem_relation_type": "isVersionOf", "subitem_relation_type_id": {"subitem_relation_type_id_text": "33550420", "subitem_relation_type_select": "PMID"}}]}, "item_3_relation_28": {"attribute_name": "出版社DOI", "attribute_value_mlt": [{"subitem_relation_type": "isVersionOf", "subitem_relation_type_id": {"subitem_relation_type_id_text": "10.1093/ejcts/ezab030", "subitem_relation_type_select": "DOI"}}]}, "item_3_rights_7": {"attribute_name": "権利", "attribute_value_mlt": [{"subitem_rights": "© The Author(s) 2021. Published by Oxford University Press on behalf of the European Association for Cardio-Thoracic Surgery."}, {"subitem_rights": "This is a pre-copyedited, author-produced version of an article accepted for publication in \"European Journal of Cardio-Thoracic Surgery\" following peer review. The version of record [Kazumasa Tsuda, Naoki Washiyama, Daisuke Takahashi, Norihiko Shiiya, \"Functional brain isolation technique for stroke prevention in thoracic endovascular aortic repair\"; 60(2): p420-422] is available online at: https://academic.oup.com/ejcts/article-abstract/60/2/420/6130058, ”https://doi.org/10.1093/ejcts/ezab030\". "}]}, "item_3_select_2": {"attribute_name": "資源タイプ", "attribute_value_mlt": [{"subitem_select_item": "Journal Article"}]}, "item_3_source_id_19": {"attribute_name": "ISSN", "attribute_value_mlt": [{"subitem_source_identifier": "1010-7940", "subitem_source_identifier_type": "ISSN"}]}, "item_3_source_id_20": {"attribute_name": "EISSN", "attribute_value_mlt": [{"subitem_source_identifier": "1873-734X", "subitem_source_identifier_type": "ISSN"}]}, "item_3_version_type_32": {"attribute_name": "著者版フラグ", "attribute_value_mlt": [{"subitem_version_resource": "http://purl.org/coar/version/c_ab4af688f83e57aa", "subitem_version_type": "AM"}]}, "item_creator": {"attribute_name": "著者", "attribute_type": "creator", "attribute_value_mlt": [{"creatorNames": [{"creatorName": "Tsuda, Kazumasa"}], "nameIdentifiers": [{"nameIdentifier": "11408", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Washiyama, Naoki"}], "nameIdentifiers": [{"nameIdentifier": "11409", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Takahashi, Daisuke"}], "nameIdentifiers": [{"nameIdentifier": "11410", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Shiiya, Norihiko"}], "nameIdentifiers": [{"nameIdentifier": "11411", "nameIdentifierScheme": "WEKO"}]}]}, "item_files": {"attribute_name": "ファイル情報", "attribute_type": "file", "attribute_value_mlt": [{"accessrole": "open_date", "date": [{"dateType": "Available", "dateValue": "2022-02-07"}], "displaytype": "detail", "download_preview_message": "", "file_order": 0, "filename": "EJCTS-60-420.pdf", "filesize": [{"value": "1.0 MB"}], "format": "application/pdf", "future_date_message": "", "is_thumbnail": false, "licensetype": "license_free", "mimetype": "application/pdf", "size": 1000000.0, "url": {"label": "EJCTS-60-420.pdf", "url": "https://hama-med.repo.nii.ac.jp/record/3822/files/EJCTS-60-420.pdf"}, "version_id": "d7dcf6ab-b4f4-41da-8cb8-8f051738e0e5"}]}, "item_keyword": {"attribute_name": "キーワード", "attribute_value_mlt": [{"subitem_subject": "thoracic endovascular aortic repair", "subitem_subject_scheme": "Other"}, {"subitem_subject": "shaggy aorta", "subitem_subject_scheme": "Other"}, {"subitem_subject": "stroke", "subitem_subject_scheme": "Other"}, {"subitem_subject": "isolated cerebral perfusion", "subitem_subject_scheme": "Other"}]}, "item_language": {"attribute_name": "言語", "attribute_value_mlt": [{"subitem_language": "eng"}]}, "item_resource_type": {"attribute_name": "資源タイプ", "attribute_value_mlt": [{"resourcetype": "journal article", "resourceuri": "http://purl.org/coar/resource_type/c_6501"}]}, "item_title": "Functional brain isolation technique for stroke prevention in thoracic endovascular aortic repair", "item_titles": {"attribute_name": "タイトル", "attribute_value_mlt": [{"subitem_title": "Functional brain isolation technique for stroke prevention in thoracic endovascular aortic repair"}]}, "item_type_id": "3", "owner": "4", "path": ["11"], "permalink_uri": "http://hdl.handle.net/10271/00003946", "pubdate": {"attribute_name": "公開日", "attribute_value": "2022-02-07"}, "publish_date": "2022-02-07", "publish_status": "0", "recid": "3822", "relation": {}, "relation_version_is_last": true, "title": ["Functional brain isolation technique for stroke prevention in thoracic endovascular aortic repair"], "weko_shared_id": -1}
Functional brain isolation technique for stroke prevention in thoracic endovascular aortic repair
http://hdl.handle.net/10271/00003946
http://hdl.handle.net/10271/00003946cb6b6416-7ca2-48e4-a208-f72fcf794910
名前 / ファイル | ライセンス | アクション |
---|---|---|
EJCTS-60-420.pdf (1.0 MB)
|
|
Item type | 学術雑誌論文 / Journal Article(1) | |||||
---|---|---|---|---|---|---|
公開日 | 2022-02-07 | |||||
タイトル | ||||||
タイトル | Functional brain isolation technique for stroke prevention in thoracic endovascular aortic repair | |||||
言語 | ||||||
言語 | eng | |||||
キーワード | ||||||
主題Scheme | Other | |||||
主題 | thoracic endovascular aortic repair | |||||
キーワード | ||||||
主題Scheme | Other | |||||
主題 | shaggy aorta | |||||
キーワード | ||||||
主題Scheme | Other | |||||
主題 | stroke | |||||
キーワード | ||||||
主題Scheme | Other | |||||
主題 | isolated cerebral perfusion | |||||
資源タイプ | ||||||
資源タイプ識別子 | http://purl.org/coar/resource_type/c_6501 | |||||
資源タイプ | journal article | |||||
著者 |
Tsuda, Kazumasa
× Tsuda, Kazumasa× Washiyama, Naoki× Takahashi, Daisuke× Shiiya, Norihiko |
|||||
書誌情報 |
European Journal of Cardio-Thoracic Surgery 巻 60, 号 2, p. 420-422, 発行日 2021-08 |
|||||
出版者 | ||||||
出版者 | Oxford University Press | |||||
権利 | ||||||
権利情報 | © The Author(s) 2021. Published by Oxford University Press on behalf of the European Association for Cardio-Thoracic Surgery. | |||||
権利 | ||||||
権利情報 | This is a pre-copyedited, author-produced version of an article accepted for publication in "European Journal of Cardio-Thoracic Surgery" following peer review. The version of record [Kazumasa Tsuda, Naoki Washiyama, Daisuke Takahashi, Norihiko Shiiya, "Functional brain isolation technique for stroke prevention in thoracic endovascular aortic repair"; 60(2): p420-422] is available online at: https://academic.oup.com/ejcts/article-abstract/60/2/420/6130058, ”https://doi.org/10.1093/ejcts/ezab030". | |||||
抄録 | ||||||
内容記述タイプ | Abstract | |||||
内容記述 | To prevent embolic stroke during thoracic endovascular aortic repair, we have adopted the brain isolation technique since June 2014 in nine selected high risk patients (9/134: 6.7%) having ulcerated or protruding atheromas within the proximal aorta. Cardiopulmonary bypass was used to prevent aortic atheromas from entering the brain. We used a heparin-coated closed-loop cardiopulmonary bypass system incorporating a soft reservoir bag with 1 mg/kg heparin to minimize the disadvantages of extracorporeal circulation. The bypass graft (right axillary-left carotid-left axillary) was used as an arterial inflow in patients undergoing zone-1 landing (n=8), while peripheral cannulation into three brachiocephalic arteries was employed in the remaining patient. Initial pump flow was set at 1.3 L/min/m2, and native cardiac output was reduced by adjusting the reservoir bag volume. Aortography was performed to confirm non-visualization of the arch vessels before catheter manipulation. There was no mortality and one solitary left cerebellar infarction. | |||||
ISSN | ||||||
収録物識別子タイプ | ISSN | |||||
収録物識別子 | 1010-7940 | |||||
EISSN | ||||||
収録物識別子タイプ | ISSN | |||||
収録物識別子 | 1873-734X | |||||
PubMed番号 | ||||||
関連タイプ | isVersionOf | |||||
識別子タイプ | PMID | |||||
関連識別子 | 33550420 | |||||
出版社DOI | ||||||
関連タイプ | isVersionOf | |||||
識別子タイプ | DOI | |||||
関連識別子 | 10.1093/ejcts/ezab030 | |||||
著者版フラグ | ||||||
出版タイプ | AM | |||||
出版タイプResource | http://purl.org/coar/version/c_ab4af688f83e57aa |