ログイン
言語:

WEKO3

  • トップ
  • ランキング
To
lat lon distance
To

Field does not validate



インデックスリンク

インデックスツリー

メールアドレスを入力してください。

WEKO

One fine body…

WEKO

One fine body…

アイテム

  1. 学術雑誌論文
  2. 各雑誌掲載論文

Simple and selective determination of arsenite and arsenate by electrospray ionization mass spectrometry

http://hdl.handle.net/10271/1797
http://hdl.handle.net/10271/1797
0ececb5a-ba81-4596-b97c-268acdacbbae
名前 / ファイル ライセンス アクション
ACA-631-87.pdf ACA-631-87.pdf (243.3 kB)
Item type 学術雑誌論文 / Journal Article(1)
公開日 2013-08-27
タイトル
タイトル Simple and selective determination of arsenite and arsenate by electrospray ionization mass spectrometry
言語 en
言語
言語 eng
キーワード
主題 Arsenite
キーワード
主題 Arsenate
キーワード
主題 Mass spectrometry
キーワード
主題 Electrospray ionization
キーワード
主題 Pyrrolidinedithiocarbamate
資源タイプ
資源タイプ識別子 http://purl.org/coar/resource_type/c_6501
資源タイプ journal article
著者 Minakata, Kayoko

× Minakata, Kayoko

en Minakata, Kayoko

Search repository
Suzuki, Masako

× Suzuki, Masako

en Suzuki, Masako

Search repository
Suzuki, Osamu

× Suzuki, Osamu

en Suzuki, Osamu

Search repository
書誌情報 en : Analytica Chimica Acta

巻 631, 号 1, p. 87-90, 発行日 2009-01-05
出版者
出版者 Elsevier
言語 en
権利
権利情報 Copyright 2008 Elsevier B.V.
抄録
内容記述タイプ Abstract
内容記述 Arsenic pollution of public water supplies has been reported in various regions of the world. Recently, some cancer patients are treated with arsenite (AsIII); most Japanese people consume seafoods containing large amounts of negligibly toxic arsenic compounds. Some of these arsenic species are metabolized, but some remain intact. For the determination of toxic AsIII, a simple, rapid and sensitive method has been developed using electrospray ionization mass spectrometry (ESI-MS). AsIII was reacted with a chelating agent, pyrrolidinedithiocarbamate (PDC, C4H8NCSS-) and tripyrrolidinedithiocarbamate-arsine, As(PDC)3, extracted with methyl isobutyl ketone (MIBK). A 1-μL aliquot of MIBK layer was directly injected into ESI-MS instrument without chromatographic separation, and was detected within 1 min. Arsenate (AsV) was reduced to AsIII with thiosulfate, and then the total inorganic As was quantified as AsIII. This method was validated for the analysis of urine samples. The limit of detection of As was 0.22μgL-1 using 10μL of sample solution, and it is far below the permissible limit of As in drinking water, 10μgL-1, recommended by the WHO. Results were obtained in <10 min with a linear calibration range of 1-100μgL-1. Several organic arsenic compounds in urine did not interfere with AsIII detection, and the inorganic As in the reference materials SRM 2670a and 1643e were quantified after the reduction of AsV to AsIII.
ISSN
収録物識別子タイプ ISSN
収録物識別子 00032670
出版社DOI
関連タイプ isVersionOf
識別子タイプ DOI
関連識別子 10.1016/j.aca.2008.10.016
著者版フラグ
出版タイプ AM
出版タイプResource http://purl.org/coar/version/c_ab4af688f83e57aa
戻る
0
views
See details
Views

Versions

Ver.1 2023-06-20 17:30:21.358662
Show All versions

Share

Mendeley Twitter Facebook Print Addthis

Cite as

エクスポート

OAI-PMH
  • OAI-PMH JPCOAR 2.0
  • OAI-PMH JPCOAR 1.0
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX

Confirm


Powered by WEKO3


Powered by WEKO3