ログイン
言語:

WEKO3

  • トップ
  • ランキング
To
lat lon distance
To

Field does not validate



インデックスリンク

インデックスツリー

メールアドレスを入力してください。

WEKO

One fine body…

WEKO

One fine body…

アイテム

  1. 学術雑誌論文
  2. 各雑誌掲載論文

18-fluorodeoxyglucose positron emission tomography in the diagnosis of prosthetic aortic graft infection; difference between open and endovascular repair

http://hdl.handle.net/10271/0002000053
http://hdl.handle.net/10271/0002000053
3aace665-367c-44e8-9b84-845f6ce4410c
名前 / ファイル ライセンス アクション
EJCTS-63-542.pdf EJCTS-63-542.pdf (613 KB)
Item type 学術雑誌論文 / Journal Article(1)
公開日 2023-12-11
タイトル
タイトル 18-fluorodeoxyglucose positron emission tomography in the diagnosis of prosthetic aortic graft infection; difference between open and endovascular repair
言語 en
言語
言語 eng
キーワード
主題 aortic graft infection
キーワード
主題 infected aortic aneurysm
キーワード
主題 FDG-PET
資源タイプ
資源タイプ識別子 http://purl.org/coar/resource_type/c_6501
資源タイプ journal article
アクセス権
アクセス権 open access
アクセス権URI http://purl.org/coar/access_right/c_abf2
著者 Tsuda, Kazumasa

× Tsuda, Kazumasa

en Tsuda, Kazumasa

Search repository
Washiyama, Naoki

× Washiyama, Naoki

en Washiyama, Naoki

Search repository
Takahashi, Daisuke

× Takahashi, Daisuke

en Takahashi, Daisuke

Search repository
Natsume, Kayoko

× Natsume, Kayoko

en Natsume, Kayoko

Search repository
Ohashi, Yuko

× Ohashi, Yuko

en Ohashi, Yuko

Search repository
Hirano, Masahiro

× Hirano, Masahiro

en Hirano, Masahiro

Search repository
Takeuchi, Yuki

× Takeuchi, Yuki

en Takeuchi, Yuki

Search repository
Shiiya, Norihiko

× Shiiya, Norihiko

en Shiiya, Norihiko

Search repository
書誌情報 en : European Journal of Cardio-Thoracic Surgery

巻 63, 号 1, p. ezac542, 発行日 2023-01
出版者
出版者 Oxford University Press
言語 en
権利
権利情報 This is a pre-copyedited, author-produced version of an article accepted for publication in European Journal of Cardio-Thoracic Surgery following peer review. The version of record [Kazumasa Tsuda, Naoki Washiyama, Daisuke Takahashi, Kayoko Natsume, Yuko Ohashi, Masahiro Hirano, Yuki Takeuchi, Norihiko Shiiya; 18-fluorodeoxyglucose positron emission tomography in the diagnosis of prosthetic aortic graft infection; difference between open and endovascular repair. 63(1): ezac542] is available online at: https://academic.oup.com/ejcts/article-abstract/63/1/ezac542/6832041 and https://doi.org/10.1093/ejcts/ezac542.
抄録
内容記述タイプ Abstract
内容記述 [Objective] 18F-FDG PET/CT has been reported useful for diagnosing aortic graft infection. However, 18F-FDG uptake may depend upon various factors including open vs endovascular repair and time from surgery. We aimed to elucidate the factors influencing its uptake and the diagnostic value of 18F-FDG PET/CT after open and endovascular repair.
[Methods] Hospital database of PET/CT (N=14490) and our departmental database were cross-checked to identify those who underwent 18F-FDG PET/CT after aortic repair. Patient’s data were retrieved from the chart. Images were reviewed by two nuclear medicine specialists in consensus, and the presence of increased 18F-FDG uptake was recorded. The maximum standardized uptake value (SUV max) was measured.
[Results] Among the 1112 patients who underwent aortic repair between 2011 and 2022, 71 patients were identified. Eighteen patients underwent 18F-FDG PET/CT for suspected graft infection and the remaining 53 patients for other purposes (malignancy etc.). Fourteen patients were treated as aortic graft infection. They had significantly higher SUV max than those without graft infection (mean 8.64 (SD2.78) vs 3.40 (SD0.84); p<0.01). In the non-infected grafts, SUV max was higher early after open surgical repair, while it remained low after endovascular repair.
[Conclusion] After endovascular aortic repair, a constant cut-off value of “SUV max=4.5” seems appropriate for diagnosing graft infection, since it remains low and stable from the early postoperative period. After open surgical repair, it seems acceptable to have “stepwise cut-off value” depending on the time from surgery.
注記
内容記述 雑誌掲載タイトル:18-Fluorodeoxyglucose positron emission tomography in the diagnosis of prosthetic aortic graft infection: the difference between open and endovascular repair
ISSN
収録物識別子タイプ PISSN
収録物識別子 1010-7940
EISSN
収録物識別子タイプ EISSN
収録物識別子 1873-734X
NII書誌ID
収録物識別子タイプ NCID
収録物識別子 AA1072688X
PubMed番号
関連タイプ isVersionOf
識別子タイプ PMID
関連識別子 36394268
出版社DOI
関連タイプ isVersionOf
識別子タイプ DOI
関連識別子 https://doi.org/10.1093/ejcts/ezac542
著者版フラグ
出版タイプ AM
出版タイプResource http://purl.org/coar/version/c_ab4af688f83e57aa
戻る
0
views
See details
Views

Versions

Ver.1 2023-12-08 05:46:56.289819
Show All versions

Share

Mendeley Twitter Facebook Print Addthis

Cite as

エクスポート

OAI-PMH
  • OAI-PMH JPCOAR 2.0
  • OAI-PMH JPCOAR 1.0
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX

Confirm


Powered by WEKO3


Powered by WEKO3