Item type |
学術雑誌論文 / Journal Article(1) |
公開日 |
2024-02-13 |
タイトル |
|
|
タイトル |
Patency of separate tube grafts for intercostal artery reconstruction: Size and length matter |
|
言語 |
en |
言語 |
|
|
言語 |
eng |
キーワード |
|
|
主題 |
spinal cord protection |
キーワード |
|
|
主題 |
aortic surgery |
キーワード |
|
|
主題 |
intercostal artery reconstruction |
キーワード |
|
|
主題 |
patency |
資源タイプ |
|
|
資源タイプ識別子 |
http://purl.org/coar/resource_type/c_6501 |
|
資源タイプ |
journal article |
アクセス権 |
|
|
アクセス権 |
open access |
|
アクセス権URI |
http://purl.org/coar/access_right/c_abf2 |
著者 |
Shiiya, Norihiko
Washiyama, Naoki
Takahashi, Daisuke
Tsuda, Kazumasa
Ohashi, Yuko
Natsume, Kayoko
Hirano, Masahiro
Takeuchi, Yuki
|
書誌情報 |
en : European Journal of Cardio-Thoracic Surgery
巻 63,
号 5,
p. ezad023,
発行日 2023-05-23
|
出版者 |
|
|
出版者 |
Oxford University Press |
|
言語 |
ja |
権利 |
|
|
権利情報 |
Copyright The Author(s) 2023. |
権利 |
|
|
権利情報 |
This is a pre-copyedited, author-produced version of an article accepted for publication in European Journal of Cardio-Thoracic Surgery following peer review. The version of record [Norihiko Shiiya, Naoki Washiyama, Daisuke Takahashi, Kazumasa Tsuda, Yuko Ohashi, Kayoko Natsume, Masahiro Hirano, Yuki Takeuchi, Patency of separate tube grafts for intercostal artery reconstruction: Size and length matter, European Journal of Cardio-Thoracic Surgery, Volume 63, Issue 5, Pages ezad023] is available online at: https://academic.oup.com/ejcts/article-abstract/63/5/ezad023/6998207 and https://doi.org/10.1093/ejcts/ezad023. |
抄録 |
|
|
内容記述タイプ |
Abstract |
|
内容記述 |
Objectives. Low patency is a major concern when using separate tube grafts for intercostal artery reconstruction. We aimed to elucidate the optimal size and length of grafts from the patency and computational fluid dynamics. Methods. The patency, size, and length of separate tube grafts were evaluated in 41 patients. Computational fluid dynamics simulation was performed in a model derived from a patient with a patent 12-mm graft of 15mm in length, with 2 simulation models with a smaller (8-mm) or longer (30-mm) graft. Results. A total of 49 grafts were used for intercostal artery reconstruction. There was 1 in-hospital death and 2 spinal cord injuries. The patency rate, which could be evaluated in 46 grafts, was 63% (29/46). It was 71% (24/34) in thoracoabdominal aortic replacement and 42% (5/12) in descending aortic replacement. Among 14 patients in whom all grafts were occluded, no patients developed spinal cord injury. All grafts longer than 25mm were occluded (n=5). Eight- and 10-mm grafts showed better patency than 12-mm grafts in thoracoabdominal aortic replacement (p=0.008), when grafts were shorter than 25mm. Computational fluid dynamics simulation revealed vortical flow within the 12-mm graft, which did not reach the intercostal orifice, while helical flow was maintained throughout the cardiac cycle within the 8-mm graft. Conclusions. Eight- and 10-mm grafts seemed better than 12-mm grafts, and grafts should be kept shorter than 25mm. Computational fluid dynamics simulation may shed light on the issue of optimal intercostal artery reconstruction technique. |
ISSN |
|
|
収録物識別子タイプ |
PISSN |
|
収録物識別子 |
1010-7940 |
EISSN |
|
|
収録物識別子タイプ |
EISSN |
|
収録物識別子 |
1873-734X |
NII書誌ID |
|
|
収録物識別子タイプ |
NCID |
|
収録物識別子 |
AA1072688X |
PubMed番号 |
|
|
関連タイプ |
isVersionOf |
|
|
識別子タイプ |
PMID |
|
|
関連識別子 |
36688718 |
出版社DOI |
|
|
関連タイプ |
isVersionOf |
|
|
識別子タイプ |
DOI |
|
|
関連識別子 |
https://doi.org/10.1093/ejcts/ezad023 |
著者版フラグ |
|
|
出版タイプ |
AM |
|
出版タイプResource |
http://purl.org/coar/version/c_ab4af688f83e57aa |