ログイン
言語:

WEKO3

  • トップ
  • ランキング
To
lat lon distance
To

Field does not validate



インデックスリンク

インデックスツリー

メールアドレスを入力してください。

WEKO

One fine body…

WEKO

One fine body…

アイテム

  1. 学術雑誌論文
  2. 各雑誌掲載論文

Relationship between the femoral and tibial component positions and postoperative knee range of motion after posterior-stabilized total knee arthroplasty in varus-aligned knees

http://hdl.handle.net/10271/0002000071
http://hdl.handle.net/10271/0002000071
9a594743-89e4-4b14-a50e-5ae9a4a939d6
名前 / ファイル ライセンス アクション
JKS-36-1302.pdf JKS-36-1302.pdf (609 KB)
 Restricted Access
Item type 学術雑誌論文 / Journal Article(1)
公開日 2024-02-13
タイトル
タイトル Relationship between the femoral and tibial component positions and postoperative knee range of motion after posterior-stabilized total knee arthroplasty in varus-aligned knees
言語 en
言語
言語 eng
キーワード
主題 total knee arthroplasty
キーワード
主題 knee range of motion
キーワード
主題 femoral component position
キーワード
主題 tibial component position
資源タイプ
資源タイプ識別子 http://purl.org/coar/resource_type/c_6501
資源タイプ journal article
アクセス権
アクセス権 open access
アクセス権URI http://purl.org/coar/access_right/c_abf2
著者 Hanada, Mitsuru

× Hanada, Mitsuru

en Hanada, Mitsuru

Search repository
Hotta, Kensuke

× Hotta, Kensuke

en Hotta, Kensuke

Search repository
Koyama, Hiroshi

× Koyama, Hiroshi

en Koyama, Hiroshi

Search repository
Matsuyama, Yukihiro

× Matsuyama, Yukihiro

en Matsuyama, Yukihiro

Search repository
書誌情報 en : The Journal of Knee Surgery

巻 36, 号 12, p. 1302-1307, 発行日 2023-10
出版者
出版者 Georg Thieme Verlag KG
言語 en
権利
権利情報 Copyright 2022. Thieme.
抄録
内容記述タイプ Abstract
内容記述 Background:
This study aimed to evaluate the relationship between the femoral and tibial component positions and postoperative knee range of motion after posterior-stabilized total knee arthroplasty (TKA).
Patients:
Forty-four patients (48 knees in total: 9 men, 9 knees; 35 women, 39 knees) who underwent posterior-stabilized TKA using a navigation system were included.
Methods:
The femoral and tibial component positions were measured from the preoperative and postoperative computed tomography data with three-dimensional evaluation software. We investigated the relationship between the knee range of motion, including extension restriction and maximum flexion angles at 2 years postoperatively, and the femoral and tibial component positions.
Results:
Patients with knee extension restriction of 10° or more at 2 years postoperatively showed greater posterior flexion position of the tibial component than those with knee extension restriction less than 10° (6.2° and 3.9°, respectively, p=0.018). The postoperative knee flexion angle was positively associated with the internal rotational position of the femoral component (p=0.032, 95% confidence interval: 0.105−2.178). Patients with a knee flexion angle more than 120° at 2 years postoperatively had greater internal rotational position of the femoral component than those with 120° or less (5.2° and 1.5°, respectively, p=0.002).
Conclusions:
After posterior-stabilized TKA, the 28 postoperative knee extension restriction angle was associated with the posterior flexion position of the tibial component, and the knee flexion angle was positively related to the internal rotational position of the femoral component.
ISSN
収録物識別子タイプ PISSN
収録物識別子 1538-8506
EISSN
収録物識別子タイプ EISSN
収録物識別子 1938-2480
NII書誌ID
収録物識別子タイプ NCID
収録物識別子 AA11604163
PubMed番号
関連タイプ isVersionOf
識別子タイプ PMID
関連識別子 36075230
出版社DOI
関連タイプ isVersionOf
識別子タイプ DOI
関連識別子 https://doi.org/10.1055/s-0042-1755357
著者版フラグ
出版タイプ AM
出版タイプResource http://purl.org/coar/version/c_ab4af688f83e57aa
戻る
0
views
See details
Views

Versions

Ver.1 2024-01-25 07:49:55.378788
Show All versions

Share

Mendeley Twitter Facebook Print Addthis

Cite as

エクスポート

OAI-PMH
  • OAI-PMH JPCOAR 2.0
  • OAI-PMH JPCOAR 1.0
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX

Confirm


Powered by WEKO3


Powered by WEKO3