ログイン
言語:

WEKO3

  • トップ
  • ランキング
To
lat lon distance
To

Field does not validate



インデックスリンク

インデックスツリー

メールアドレスを入力してください。

WEKO

One fine body…

WEKO

One fine body…

アイテム

  1. 学術雑誌論文
  2. 各雑誌掲載論文

Optimal target b-value on computed diffusion-weighted magnetic resonance imaging for visualization of pancreatic ductal adenocarcinoma and focal autoimmune pancreatitis

http://hdl.handle.net/10271/0002000455
http://hdl.handle.net/10271/0002000455
b108f30b-d458-40fd-b2e8-99ad21fb5478
名前 / ファイル ライセンス アクション
Abdom Abdom Radiol-46-636 .pdf (7.3 MB)
Item type 共通アイテムタイプ / Common item types(1)
公開日 2025-06-23
タイトル
タイトル Optimal target b-value on computed diffusion-weighted magnetic resonance imaging for visualization of pancreatic ductal adenocarcinoma and focal autoimmune pancreatitis
言語
言語 eng
キーワード
主題 magnetic resonance imaging
キーワード
主題 computed diffusion-weighted imaging
キーワード
主題 pancreas
キーワード
主題 adenocarcinoma
キーワード
主題 autoimmune pancreatitis
資源タイプ
資源タイプ journal article
アクセス権
アクセス権 open access
著者 Ichikawa, Shintaro

× Ichikawa, Shintaro

en Ichikawa, Shintaro

Search repository
Kromrey, Marie-Luise

× Kromrey, Marie-Luise

de Kromrey, Marie-Luise

Search repository
Motosugi, Utaroh

× Motosugi, Utaroh

en Motosugi, Utaroh

Search repository
Onishi, Hiroshi

× Onishi, Hiroshi

en Onishi, Hiroshi

Search repository
著者情報 市川, 新太郎

× 市川, 新太郎

ja 市川, 新太郎

ja-Kana イチカワ, シンタロウ

Search repository
書誌情報 en : Abdominal radiology

巻 46, 号 2, p. 636-646, 発行日 2021-02
出版者
出版者 Springer Nature
権利
権利情報 This version of the article has been accepted for publication, after peer review (when applicable) and is subject to Springer Nature’s AM terms of use, but is not the Version of Record and does not reflect post-acceptance improvements, or any corrections. The Version of Record is available online at: https://doi.org/10.1007/s00261-020-02695-0
抄録
内容記述タイプ Abstract
内容記述 Purpose: To compare computed diffusion-weighted imaging (cDWI) feasibility with that of directly acquired DWI for visualizing pancreatic ductal adenocarcinoma (PDAC) and focal autoimmune pancreatitis (AIP).
Methods: From April 2012 to January 2017, 135 patients with PDAC (n=111) or focal AIP (n=24) were retrospectively enrolled. They underwent DWI with b-values of 0, 500, and 1000 s/mm2. From DWI0 and DWI1000, we generated cDWIs with targeted b-values of 1500, 2000, and 3000 s/mm2. The lesions’ signal intensities, image quality, signal-intensity ratio (SIR) of lesions and pancreatic parenchyma to spinal cord, and lesion-to-pancreatic parenchyma contrast ratio (CR) were compared among the five DWI protocols (DWI500, DWI1000, cDWI1500, cDWI2000, and cDWI3000). SIR was analyzed by receiver operating characteristic (ROC) analyses.
Results: DWI500, DWI1000, and cDWI1500 had higher image quality than cDWI2000 and cDWI3000 (P<0.001). The incidence of clear hyperintense PDAC was highest on cDWI2000, followed by cDWI1500, and cDWI3000 (P<0.001–0.002), while the incidence of clear hyperintense AIP was higher on DWI1000, cDWI1500, and cDWI2000 than on DWI500 and cDWI3000 (P=0.001–0.022). SIRs decreased whereas CRs increased as the b-value increased, for both PDAC and AIP. The area under the ROC curve (AUC) of SIRlesion was significantly lower on cDWI1500 than on cDWI2000 and cDWI3000 (P<0.001).
Conclusion: cDWI1500 or cDWI2000 generated from b-values of 0 and 1000 s/mm2 were the most effective for visualizing PDAC and focal AIP; however, the SIRlesion AUC was significantly lower on cDWI1500 than on cDWI2000 and cDWI3000.
PISSN
収録物識別子 2366-004X
EISSN
収録物識別子 2366-0058
PubMed番号 (PMID)
関連識別子 32740865
出版社DOI
関連識別子 https://doi.org/10.1007/s00261-020-02695-0
出版タイプ
出版タイプ AM
戻る
0
views
See details
Views

Versions

Ver.1 2025-06-20 05:30:09.616592
Show All versions

Share

Mendeley Twitter Facebook Print Addthis

Cite as

エクスポート

OAI-PMH
  • OAI-PMH JPCOAR 2.0
  • OAI-PMH JPCOAR 1.0
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX

Confirm


Powered by WEKO3


Powered by WEKO3