HRT-3 Moorfields reference plane: effect on rim area repeatability and identification of progression

http://hdl.handle.net/10271/2417
http://hdl.handle.net/10271/2417
7698bd18-528e-49af-80e9-c16e697cae07
名前 / ファイル ライセンス アクション
BrJOphthalmol93-1510.pdf BrJOphthalmol93-1510.pdf (113.6 kB)
Item type 学術雑誌論文 / Journal Article(1)
公開日 2013-08-27
タイトル
タイトル HRT-3 Moorfields reference plane: effect on rim area repeatability and identification of progression
言語 en
言語
言語 eng
資源タイプ
資源タイプ識別子 http://purl.org/coar/resource_type/c_6501
資源タイプ journal article
著者 Asaoka, Ryo

× Asaoka, Ryo

Asaoka, Ryo

Search repository
Strouthidis, N G

× Strouthidis, N G

Strouthidis, N G

Search repository
Kappou, V

× Kappou, V

Kappou, V

Search repository
Gardiner, S K

× Gardiner, S K

Gardiner, S K

Search repository
Garway-Heath, D F

× Garway-Heath, D F

Garway-Heath, D F

Search repository
書誌情報 British Journal of Ophthalmology

巻 93, 号 11, p. 1510-1513, 発行日 2009-06-16
出版者
出版者 the BMJ Publishing Group Ltd
権利
権利情報 Copyright the BMJ Publishing Group Ltd
抄録
内容記述タイプ Abstract
内容記述 Aims: To assess the effect of the Moorfields Reference Plane on Heidelberg Retina Tomograph (HRT) rim area repeatability and its effect on progression rates using an event analysis. Methods: The HRT reference plane (RP) defines structures above as “rim” and below as “cup.” The Moorfields RP applies the Standard RP (located 50 μm posterior to the temporal disc margin) at baseline and maintains the distance between the Standard RP and the reference ring (located in the image periphery) for follow-up images. The Moorfields RP was applied to an HRT test-retest dataset, and rim area repeatability coefficients were calculated. Repeatability coefficients were compared between the Moorfields, Standard and 320 (located 320 μm posterior to the reference ring) RPs. The Moorfields RP was applied to HRT images from 198 ocular hypertensives, acquired over 6 years. HRT progression required rim area baseline/follow-up differences exceeding the repeatability coefficient in two or more sectors, with confirmation in at least one of two consecutive images. Field progression was assessed using Advanced Glaucoma Intervention Study criteria. Results: The Moorfields RP improved rim area repeatability compared with the Standard RP; repeatability was similar between the Moorfields and the 320 RP. The frequency of identified progression using Moorfields RP was 40% compared with 28% for the 320 RP. There was a greater percentage with concurrent field progression -15.1% (Moorfields RP) compared with 12.1% (320 RP). Conclusions: Although rim area repeatability was similar using the 320 RP and the Moorfields RP, the latter resulted in greater rates of detection of change.
ISSN
収録物識別子タイプ ISSN
収録物識別子 14682079
出版社DOI
関連タイプ isIdenticalTo
識別子タイプ DOI
関連識別子 10.1136/bjo.2008.148031
著者版フラグ
出版タイプ VoR
出版タイプResource http://purl.org/coar/version/c_970fb48d4fbd8a85
戻る
0
views
See details
Views

Versions

Ver.1 2023-06-20 17:14:14.885307
Show All versions

Share

Mendeley Twitter Facebook Print Addthis

Cite as

エクスポート

OAI-PMH
  • OAI-PMH JPCOAR 2.0
  • OAI-PMH JPCOAR 1.0
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX

Confirm


Powered by WEKO3


Powered by WEKO3