DEVELOPMENT OF A NEW ACTIVITY-INPUT-TYPE AMBULATORY ELECTROCARDIOGRAM AND ITS CLINICAL USEFULNESS

http://hdl.handle.net/10271/2508
http://hdl.handle.net/10271/2508
bc15e8d6-77c3-4619-9f79-65f14c717623
名前 / ファイル ライセンス アクション
JCircJ-55-303.pdf JCircJ-55-303.pdf (1.2 MB)
Item type 学術雑誌論文 / Journal Article(1)
公開日 2013-08-27
タイトル
タイトル DEVELOPMENT OF A NEW ACTIVITY-INPUT-TYPE AMBULATORY ELECTROCARDIOGRAM AND ITS CLINICAL USEFULNESS
言語 en
言語
言語 eng
キーワード
主題 Ambulatory electrocardiographic monitoring
キーワード
主題 Angina pectoris
キーワード
主題 Evaluation of drug efficacy
キーワード
主題 Activity
資源タイプ
資源タイプ識別子 http://purl.org/coar/resource_type/c_6501
資源タイプ journal article
著者 Ishizaka, Kyouichi

× Ishizaka, Kyouichi

Ishizaka, Kyouichi

Search repository
Kobayashi, Akira

× Kobayashi, Akira

Kobayashi, Akira

Search repository
Yamazaki, Noboru

× Yamazaki, Noboru

Yamazaki, Noboru

Search repository
書誌情報 Japanese Circulation Journal

巻 55, 号 4, p. 303-315, 発行日 1989-12-22
出版者
出版者 日本循環器学会
権利
権利情報 Copyright日本循環器学会
権利
権利情報 本文データは学協会の許諾に基づきJournal Archiveから複製したものである
抄録
内容記述タイプ Abstract
内容記述 There are some problems with interpretation of the results of ambulatory electrocardiographic monitoring of patients with angina pectoris. To eliminate some of these difficulties, we developed a new activity-input-type ambulatory electrocardiogram which could simultaneously record the electrocardiogram and the patient's activities. Daily activities were classified into 8 levels from lying down to running or climbing a slope, in order to record them as analyzable square waves. Accuracy of the activity input to this equipment in 10 patients with effort angina was good, with 86.7% accuracy for eating and 91.7% for defecation. A comparison was made between the first and second recordings of daily activity changes in each exertional level. The numbers, mean duration and maximum duration of actions in each level were not always equal. and often changed between the two recordings. Maximum ST depression in each exertional level showed a favorable correlation of r=0.931 (by 1.76±0.59 vs 1.77±0.66) between the first and the second recordings. The descriptions of activities recorded in patients diaries are unreliable indicators of time, because subjects check the time sometimes during, and sometimes after, the actions concerned. This equipment can easily make real-time recordings of such information, and thus provide advantages in research. When observing the pathologic condition of patients with angina pectoris and evaluating anti-anginal drug efficacy, information on the activity of each patient is important. This equipment therefore contributes to improving problems of ambulatory electrocardiographic monitoring for the patients with angina pectoris.
ISSN
収録物識別子タイプ ISSN
収録物識別子 00471828
EISSN
収録物識別子タイプ ISSN
収録物識別子 13474839
出版社DOI
関連タイプ isIdenticalTo
識別子タイプ DOI
関連識別子 10.1253/jcj.55.303
著者版フラグ
出版タイプ VoR
出版タイプResource http://purl.org/coar/version/c_970fb48d4fbd8a85
戻る
0
views
See details
Views

Versions

Ver.1 2023-06-20 17:11:17.309070
Show All versions

Share

Mendeley Twitter Facebook Print Addthis

Cite as

エクスポート

OAI-PMH
  • OAI-PMH JPCOAR 2.0
  • OAI-PMH JPCOAR 1.0
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX

Confirm


Powered by WEKO3


Powered by WEKO3