ログイン
言語:

WEKO3

  • トップ
  • ランキング
To
lat lon distance
To

Field does not validate



インデックスリンク

インデックスツリー

メールアドレスを入力してください。

WEKO

One fine body…

WEKO

One fine body…

アイテム

  1. 学術雑誌論文
  2. 各雑誌掲載論文

Determination of azide in gastric fluid and urine by flow-injection electrospray ionization tandem mass spectrometry

http://hdl.handle.net/10271/2908
http://hdl.handle.net/10271/2908
4f998574-c21c-432a-9ade-b23808d8c440
名前 / ファイル ライセンス アクション
abc-403-1793.pdf abc-403-1793.pdf (5.0 MB)
Item type 学術雑誌論文 / Journal Article(1)
公開日 2015-11-20
タイトル
タイトル Determination of azide in gastric fluid and urine by flow-injection electrospray ionization tandem mass spectrometry
言語 en
言語
言語 eng
キーワード
主題 Azide
キーワード
主題 Gold
キーワード
主題 Electrospray ionization
キーワード
主題 Tandem mass spectrometry
キーワード
主題 Gastric fluid
キーワード
主題 Urine
資源タイプ
資源タイプ識別子 http://purl.org/coar/resource_type/c_6501
資源タイプ journal article
著者 Minakata, Kayoko

× Minakata, Kayoko

Minakata, Kayoko

Search repository
Nozawa, Hideki

× Nozawa, Hideki

Nozawa, Hideki

Search repository
Yamagishi, Itaru

× Yamagishi, Itaru

Yamagishi, Itaru

Search repository
Gonmori, Kunio

× Gonmori, Kunio

Gonmori, Kunio

Search repository
Hasegawa, Koutaro

× Hasegawa, Koutaro

Hasegawa, Koutaro

Search repository
Suzuki, Masako

× Suzuki, Masako

Suzuki, Masako

Search repository
Watanabe, Kanako

× Watanabe, Kanako

Watanabe, Kanako

Search repository
Suzuki, Osamu

× Suzuki, Osamu

Suzuki, Osamu

Search repository
書誌情報 Analytical and Bioanalytical Chemistry

巻 403, 号 7, p. 1793-1799, 発行日 2012-06
出版者
出版者 Springer
権利
権利情報 The final publication is available at Springer via http://dx.doi.org/10.1007/s00216-012-5848-3.
抄録
内容記述タイプ Abstract
内容記述 A rapid method was developed to identify and quantify the azide ion (N3?) in gastric fluid and urine. N3? in diluted biological fluids was reacted with NaAuCl4 to produce Au(N3)2?, which was extracted with octanol. Five microliters of the extract were flow-injected into an electrospray ionization tandem mass spectrometric instrument. Quantification of N3? was performed by selected reaction monitoring of the product ion Au(N)(N3) ? at m/z 253 which was derived from the precursor ion Au(N3)2? at m/z 281, using 50 μL of aqueous solution within 10 min. This method was found to be linear up to 10?5 M, to have a limit of quantification of 10?7 M, a limit of detection of 3.0×10?8 M, and a coefficient of variation of ≦ 10 % at 10?7 M. In case of urine, 50 μL of urine were spiked with N3?, this was diluted to10-fold and passed through 1 mL of a resin and finally diluted to 100-fold of the original. This method was linear up to 10?3 M, had a limit of quantification of 10?5 M, a limit of detection of 3.0×10?6 M, and coefficient of variation ≦ 8.8 % for an original urine concentration of 10?5 M. The practical applicability of this method was checked by diluting 1 μL of a suspected suicide victim’s gastric fluid 20,000-fold and 1 μL of the victim’s urine 5,000-fold and then measuring the N3? levels. These levels were found to be (7.5±1.0)×10?2 M and (3.2±0.4)×10?3 M, respectively.
PubMed番号
関連タイプ isVersionOf
識別子タイプ PMID
関連識別子 22370586
出版社DOI
関連タイプ isVersionOf
識別子タイプ DOI
関連識別子 10.1007/s00216-012-5848-3
著者版フラグ
出版タイプ AM
出版タイプResource http://purl.org/coar/version/c_ab4af688f83e57aa
戻る
0
views
See details
Views

Versions

Ver.1 2023-06-20 16:58:51.881766
Show All versions

Share

Mendeley Twitter Facebook Print Addthis

Cite as

エクスポート

OAI-PMH
  • OAI-PMH JPCOAR 2.0
  • OAI-PMH JPCOAR 1.0
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX

Confirm


Powered by WEKO3


Powered by WEKO3