ログイン
言語:

WEKO3

  • トップ
  • ランキング
To
lat lon distance
To

Field does not validate



インデックスリンク

インデックスツリー

メールアドレスを入力してください。

WEKO

One fine body…

WEKO

One fine body…

アイテム

  1. 学位論文
  2. 博士論文(医学)
  3. 本文

Selective improvement of peptides imaging on tissue by supercritical fluid wash of lipids for matrix-assisted laser desorption/ionization mass spectrometry

http://hdl.handle.net/10271/3222
http://hdl.handle.net/10271/3222
2647a7d7-650d-4cb6-bb91-40d4baffcf6e
名前 / ファイル ライセンス アクション
DT_753ronbun.pdf 論文本文 (632.1 kB)
Item type 学位論文 / Thesis or Dissertation(1)
公開日 2018-03-06
タイトル
タイトル Selective improvement of peptides imaging on tissue by supercritical fluid wash of lipids for matrix-assisted laser desorption/ionization mass spectrometry
言語 en
言語
言語 eng
キーワード
主題 imaging mass spectrometry
キーワード
主題 supercritical fluid of CO2
キーワード
主題 peptides
キーワード
主題 pretreatment
キーワード
主題 matrix-assisted laser desorption/ionization
資源タイプ
資源タイプ識別子 http://purl.org/coar/resource_type/c_db06
資源タイプ doctoral thesis
アクセス権
アクセス権 open access
アクセス権URI http://purl.org/coar/access_right/c_abf2
その他のタイトル
その他のタイトル 脂質の超臨界流体洗浄による組織中ペプチドのマトリックス支援レーザー脱離/イオン化イメージング質量分析の選択的改善
著者 Matsushita, Shoko

× Matsushita, Shoko

en Matsushita, Shoko

Search repository
書誌情報 en : Analytical and Bioanalytical Chemistry

巻 409, 号 6, p. 1475-1480, 発行日 2016-12-09
出版者
出版者 Springer Berlin Heidelberg
言語 en
抄録
内容記述タイプ Abstract
内容記述 There is a high analytical demand for improving the detection sensitivity for various peptides in matrix-assisted laser desorption/ionization imaging mass spectrometry (MALDI-IMS) because exhaustive distribution analyses of various peptides could help to reveal the function of peptides in vivo. To improve the sensitivity of peptide detection, we used supercritical fluid of CO2 (scCO2) as washing solvent for a pretreatment to remove lipids. We evaluated whether our wash method using scCO2 with an entrainer improved the detection of peptides and suppressed lipid detection in MALDI-IMS. Our analysis revealed that the signal intensities of peptides such as m/z 3339.8, 3530.9, 4233.3, 4936.7, and 4963.7 were increased in scCO2-washed samples. The greatest improvement in the signal-to-noise ratio (S/N) was found at m/z 4963.7, which was identified as thymosin β4, with the S/N reaching almost 190-fold higher than the control. Additionally, all of the improved signals were associated with the morphologic structure. Our method allows us to analyze the distribution of molecules, especially in the region of m/z 3000?5200. For these improvements, the polarity difference between scCO2 and the matrix solution used was considered as a key. A wider variety of molecules can be analyzed in the future due to this improvement of the detection sensitivity by optimizing the polarity of scCO2 with various entrainers.
言語 en
学位名
学位名 博士(医学)
学位の区分
内容記述 doctoral
学位の分野
内容記述 医学系研究科
学位授与機関
学位授与機関識別子Scheme kakenhi
学位授与機関識別子 13802
学位授与機関名 浜松医科大学
学位授与年月日
学位授与年月日 2017-03-13
学位授与番号
学位授与番号 甲第753号
ISSN
収録物識別子タイプ PISSN
収録物識別子 1618-2642
EISSN
収録物識別子タイプ EISSN
収録物識別子 1618-2650
PubMed番号
識別子タイプ PMID
関連識別子 27942804
出版社DOI
識別子タイプ DOI
関連識別子 https://doi.org/10.1007/s00216-016-0119-3
著者版フラグ
出版タイプ AM
出版タイプResource http://purl.org/coar/version/c_ab4af688f83e57aa
戻る
0
views
See details
Views

Versions

Ver.1 2023-06-20 16:50:11.343158
Show All versions

Share

Mendeley Twitter Facebook Print Addthis

Cite as

エクスポート

OAI-PMH
  • OAI-PMH JPCOAR 2.0
  • OAI-PMH JPCOAR 1.0
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX

Confirm


Powered by WEKO3


Powered by WEKO3