Hemodynamic analysis of endoleaks after endovascular abdominal aortic aneurysm repair by using 4-dimensional flow-sensitive magnetic resonance imaging

http://hdl.handle.net/10271/00003567
http://hdl.handle.net/10271/00003567
8cf30301-af10-4376-b78e-cc5b98b31008
名前 / ファイル ライセンス アクション
DT_ron555ronbun.pdf 論文本文 (3.8 MB)
Item type 学位論文 / Thesis or Dissertation(1)
公開日 2019-07-09
タイトル
タイトル Hemodynamic analysis of endoleaks after endovascular abdominal aortic aneurysm repair by using 4-dimensional flow-sensitive magnetic resonance imaging
言語 en
言語
言語 eng
キーワード
主題 4D-flow
キーワード
主題 Endoleaks
キーワード
主題 Hemodynamics
キーワード
主題 Magnetic resonance imaging
キーワード
主題 Stent-graft
資源タイプ
資源タイプ識別子 http://purl.org/coar/resource_type/c_db06
資源タイプ doctoral thesis
アクセス権
アクセス権 open access
アクセス権URI http://purl.org/coar/access_right/c_abf2
その他のタイトル
その他のタイトル 4D Flow MRIを用いた腹部大動脈瘤に対するステントグラフト内挿術後のエンドリークに対する血行動態解析
著者 美甘(阪田), 麻裕

× 美甘(阪田), 麻裕

ja 美甘(阪田), 麻裕

Search repository
書誌情報 en : Circulation journal : official journal of the Japanese Circulation Society

巻 80, 号 8, p. 1715-1725, 発行日 2016-07-25
出版者
出版者 日本循環器学会
言語 ja
出版者
出版者 Japanese Circulation Society
言語 en
抄録
内容記述タイプ Abstract
内容記述 Background: An endoleak is a common complication of endovascular abdominal aortic aneurysm repair (EVAR), and it can be associated with aneurysmal growth. This pilot study used 4-dimensional flow-sensitive magnetic resonance imaging (4D-flow) to assess the hemodynamics of different types of endoleaks (I-IV).
Methods and Results: Magnetic resonance angiography, 4D-flow, and computed tomography angiography (CTA) were performed in 31 patients after nitinol-based stent-graft deployment. With 4D-flow, the 3D streamlines of endoleaks appear as integrated traces along the instantaneous velocity vector field that are color-coded according to the local velocity magnitude of the leak. The 4D-flow analysis identified endoleaks in 18 patients (58.1%), whereas CTA identified endoleaks in 13 patients (41.9%). The 4D-flow analysis created a characteristic image of each type of endoleak. Among patients with endoleaks, 4D-flow identified concomitant multiple endoleaks in 7 (39%) patients, and it further differentiated type II endoleaks from type IIa endoleaks (to-and-fro biphasic flow pattern from a branch vessel) and from type IIb endoleaks (monophasic flow pattern with a connection between the inflow and outflow branches).
Conclusions: The 4D-flow analysis was more sensitive than CTA for detecting an endoleak, and it could subclassify type II endoleaks. In addition, 4D-flow differentiated between concomitant endoleak types in a single patient. (Circ J 2016; 80: 1715-1725)
言語 en
学位名
学位名 博士(医学)
学位の区分
内容記述 doctoral
学位の分野
内容記述 医学系研究科
学位授与機関
学位授与機関識別子Scheme kakenhi
学位授与機関識別子 13802
学位授与機関名 浜松医科大学
学位授与年月日
学位授与年月日 2018-10-19
学位授与番号
学位授与番号 乙第555号
ISSN
収録物識別子タイプ PISSN
収録物識別子 1346-9843
EISSN
収録物識別子タイプ EISSN
収録物識別子 1347-4820
PubMed番号
識別子タイプ PMID
関連識別子 27357219
医中誌論文ID
識別子タイプ ICHUSHI
関連識別子 2017118973
出版社DOI
識別子タイプ DOI
関連識別子 https://doi.org/10.1253/circj.CJ-16-0297
著者版フラグ
出版タイプ VoR
出版タイプResource http://purl.org/coar/version/c_970fb48d4fbd8a85
戻る
0
views
See details
Views

Versions

Ver.1 2023-06-20 16:40:00.015001
Show All versions

Share

Mendeley Twitter Facebook Print Addthis

Cite as

エクスポート

OAI-PMH
  • OAI-PMH JPCOAR 2.0
  • OAI-PMH JPCOAR 1.0
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX

Confirm


Powered by WEKO3


Powered by WEKO3