Factors affecting measurement of optic parameters by time-resolved near-infrared spectroscopy in breast cancer
http://hdl.handle.net/10271/00003572
http://hdl.handle.net/10271/00003572638b33ae-45df-486d-8f6d-9b533315fd0b
名前 / ファイル | ライセンス | アクション |
---|---|---|
![]() |
|
Item type | 学位論文 / Thesis or Dissertation(1) | |||||
---|---|---|---|---|---|---|
公開日 | 2019-07-11 | |||||
タイトル | ||||||
タイトル | Factors affecting measurement of optic parameters by time-resolved near-infrared spectroscopy in breast cancer | |||||
言語 | en | |||||
言語 | ||||||
言語 | eng | |||||
キーワード | ||||||
言語 | en | |||||
主題Scheme | Other | |||||
主題 | breast cancer | |||||
キーワード | ||||||
言語 | en | |||||
主題Scheme | Other | |||||
主題 | hemoglobin | |||||
キーワード | ||||||
言語 | en | |||||
主題Scheme | Other | |||||
主題 | tissue oxygen saturation | |||||
キーワード | ||||||
言語 | en | |||||
主題Scheme | Other | |||||
主題 | reduced scattering coefficient | |||||
資源タイプ | ||||||
資源タイプ識別子 | http://purl.org/coar/resource_type/c_db06 | |||||
資源タイプ | doctoral thesis | |||||
アクセス権 | ||||||
アクセス権 | open access | |||||
アクセス権URI | http://purl.org/coar/access_right/c_abf2 | |||||
その他のタイトル | ||||||
その他のタイトル | 近赤外光時間分解分光装置を用いる乳がんの光学パラメータ測定に影響を及ぼす因子 | |||||
言語 | ja | |||||
著者 |
芳澤, 暢子
× 芳澤, 暢子 |
|||||
書誌情報 |
en : Journal of Biomedical Optics 巻 23, 号 2, p. 026010, 発行日 2018-02-27 |
|||||
出版者 | ||||||
出版者 | SPIE--the International Society for Optical Engineering in cooperation with International Biomedical Optics Society | |||||
言語 | en | |||||
抄録 | ||||||
内容記述タイプ | Abstract | |||||
内容記述 | The purpose of this study was to evaluate the effects of the thickness and depth of tumors on hemoglobin measurements in breast cancer by optical spectroscopy and to demonstrate tissue oxygen saturation (SO2) and reduced scattering coefficient (μs′) in breast tissue and breast cancer in relation to the skin-to-chest wall distance. We examined 53 tumors from 44 patients. Total hemoglobin concentration (tHb), SO2, and μs′ were measured by time-resolved spectroscopy (TRS). The skin-to-chest wall distance and the size and depth of tumors were measured by ultrasonography. There was a positive correlation between tHb and tumor thickness, and a negative correlation between tHb and tumor depth. SO2 in breast tissue decreased when the skin-to-chest wall distance decreased, and SO2 in tumors tended to be lower than in breast tissue. In breast tissue, there was a negative correlation between μs′ and the skin-to-chest wall distance, and μs′ in tumors was higher than in breast tissue. Measurement of tHb in breast cancer by TRS was influenced by tumor thickness and depth. Although SO2 seemed lower and μs′ was higher in breast cancer than in breast tissue, the skin-to-chest wall distance may have affected the measurements. | |||||
言語 | en | |||||
学位名 | ||||||
言語 | ja | |||||
学位名 | 博士(医学) | |||||
学位の区分 | ||||||
内容記述タイプ | Other | |||||
内容記述 | doctoral | |||||
言語 | en | |||||
学位の分野 | ||||||
内容記述タイプ | Other | |||||
内容記述 | 医学系研究科 | |||||
言語 | ja | |||||
学位授与機関 | ||||||
学位授与機関識別子Scheme | kakenhi | |||||
学位授与機関識別子 | 13802 | |||||
言語 | ja | |||||
学位授与機関名 | 浜松医科大学 | |||||
学位授与年月日 | ||||||
学位授与年月日 | 2019-02-14 | |||||
学位授与番号 | ||||||
学位授与番号 | 乙第558号 | |||||
ISSN | ||||||
収録物識別子タイプ | PISSN | |||||
収録物識別子 | 1083-3668 | |||||
EISSN | ||||||
収録物識別子タイプ | EISSN | |||||
収録物識別子 | 1560-2281 | |||||
PubMed番号 | ||||||
識別子タイプ | PMID | |||||
関連識別子 | 29488362 | |||||
出版社DOI | ||||||
識別子タイプ | DOI | |||||
関連識別子 | https://doi.org/10.1117/1.JBO.23.2.026010 | |||||
著者版フラグ | ||||||
出版タイプ | VoR | |||||
出版タイプResource | http://purl.org/coar/version/c_970fb48d4fbd8a85 |