Application of electrospray ionization tandem mass spectrometry for the rapid and sensitive determination of cobalt in urine

http://hdl.handle.net/10271/52
http://hdl.handle.net/10271/52
3a3d22bd-0057-4fe6-8144-48878540bbb9
名前 / ファイル ライセンス アクション
ACA-07-1999Rev.pdf ACA-07-1999Rev.pdf (168.3 kB)
Item type 学術雑誌論文 / Journal Article(1)
公開日 2013-08-27
タイトル
タイトル Application of electrospray ionization tandem mass spectrometry for the rapid and sensitive determination of cobalt in urine
言語 en
言語
言語 eng
キーワード
主題 Cobalt
キーワード
主題 Tandem mass spectrometry
キーワード
主題 Electrospray ionization
資源タイプ
資源タイプ識別子 http://purl.org/coar/resource_type/c_6501
資源タイプ journal article
アクセス権
アクセス権 open access
アクセス権URI http://purl.org/coar/access_right/c_abf2
著者 Minakata, Kayoko

× Minakata, Kayoko

en Minakata, Kayoko

Search repository
Suzuki, Masako

× Suzuki, Masako

en Suzuki, Masako

Search repository
Suzuki, Osamu

× Suzuki, Osamu

en Suzuki, Osamu

Search repository
書誌情報 en : Analytica Chimica Acta

巻 614, 号 2, p. 161-164, 発行日 2008-05-05
出版者
出版者 Elsevier
言語 en
権利
権利情報 (C) Elsevier
抄録
内容記述タイプ Abstract
内容記述 Recently, cobalt (Co) is reported to be taken as a supplement by athletes for improving anaerobic performance. For the diagnosis of abuse, the limit of detection (LOD) of Co in the analysis should be lower than the concentrations of Co in plasma and urine of normal persons. A simple, rapid and sensitive method has been developed for the determination of Co in urine. Co was complexed with diethyldithiocarbamate (DDC) and extracted with isoamyl alcohol in the presence of citric acid. The detection of Co was achieved by injecting a 1 μl aliquot of isoamyl alcohol containing Co-DDC complex directly into an electrospray ionization tandem mass spectrometric (ESI-MS-MS) instrument without chromatographic separation. The quantification was performed using selected reaction monitoring at m/z 291 of the product ion Co(C4H10NCS)2+ which was produced by collision-induced dissociation from the precursor ion Co(DDC)2+ at m/z 355. ESI-MS-MS data were obtained in less than 10 min with an LOD of 0.05 μgl-1 and a linear calibration range of 0.1 – 100 μgl-1 using 10 μl of urine. The procedure was validated with certified reference materials (SRM 2670a and SRM 1643e). This method is suitable for the analysis of Co in the laboratories already equipped with an ESI-MS-MS instrument.
ISSN
収録物識別子タイプ PISSN
収録物識別子 0003-2670
EISSN
収録物識別子タイプ EISSN
収録物識別子 1873-4324
PubMed番号
関連タイプ isVersionOf
識別子タイプ PMID
関連識別子 18420046
出版社DOI
関連タイプ isVersionOf
識別子タイプ DOI
関連識別子 https://doi.org/10.1016/j.aca.2008.03.043
著者版フラグ
出版タイプ AM
出版タイプResource http://purl.org/coar/version/c_ab4af688f83e57aa
戻る
0
views
See details
Views

Versions

Ver.1 2023-06-20 18:25:59.755050
Show All versions

Share

Mendeley Twitter Facebook Print Addthis

Cite as

エクスポート

OAI-PMH
  • OAI-PMH JPCOAR 2.0
  • OAI-PMH JPCOAR 1.0
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX

Confirm


Powered by WEKO3


Powered by WEKO3