Use of flexible endoscopic aspiration for an intraventricular small floating clot with hemorrhage: a technical note

http://hdl.handle.net/10271/00004334
http://hdl.handle.net/10271/00004334
550bde56-0c99-4788-9cf2-d3735d771d0c
名前 / ファイル ライセンス アクション
Neurosurg Neurosurg Rev-44-2363.pdf (663.7 kB)
Item type 学術雑誌論文 / Journal Article(1)
公開日 2023-03-30
タイトル
タイトル Use of flexible endoscopic aspiration for an intraventricular small floating clot with hemorrhage: a technical note
言語
言語 eng
資源タイプ
資源タイプ識別子 http://purl.org/coar/resource_type/c_6501
資源タイプ journal article
その他のタイトル
その他のタイトル Endoscopic aspiration for intraventricular small floating clots
著者 Neki, Hiroaki

× Neki, Hiroaki

Neki, Hiroaki

Search repository
Shibata, Aoto

× Shibata, Aoto

Shibata, Aoto

Search repository
Komine, Hiroyuki

× Komine, Hiroyuki

Komine, Hiroyuki

Search repository
Kohyama, Shinya

× Kohyama, Shinya

Kohyama, Shinya

Search repository
Yamane, Fumitaka

× Yamane, Fumitaka

Yamane, Fumitaka

Search repository
Ishihara, Shoichiro

× Ishihara, Shoichiro

Ishihara, Shoichiro

Search repository
Kikkawa, Yuichiro

× Kikkawa, Yuichiro

Kikkawa, Yuichiro

Search repository
書誌情報 Neurosurgical Review

巻 44, 号 4, p. 2363-2367, 発行日 2021-08
出版者
出版者 Springer Nature
権利
権利情報 This version of the article has been accepted for publication, after peer review (when applicable) and is subject to Springer Nature’s AM terms of use, but is not the Version of Record and does not reflect post-acceptance improvements, or any corrections. The Version of Record is available online at: http://dx.doi.org/10.1007/s10143-020-01392-2
抄録
内容記述タイプ Abstract
内容記述 [Background] Although flexible endoscopy is effective for intraventricular lesions, it is less frequently used for hemorrhagic cases. In some hemorrhagic strokes, blood clots may plunge into the cerebral aqueduct and cause acute obstructive hydrocephalus. A flexible endoscope can aspirate clots and prevent acute hydrocephalus.
[Methods] Here we report four cases of hemorrhage: one of intracerebral hemorrhage and three of subarachnoid hemorrhages.
[Results] In all cases, acute hydrocephalus was not apparent upon admission. Sudden comatose occurred; computed tomography revealed acute obstructive hydrocephalus with a strangulated clot in the cerebral aqueduct. We performed aspiration of the strangulated clot using a flexible endoscope. Consciousness improved in all cases, and acute hydrocephalus was prevented in all cases.
[Conclusion] The use of simple flexible endoscopic aspiration for clots might be a beneficial and less-invasive procedure for acute obstructive hydrocephalus caused by a small clot with hemorrhagic stroke.
ISSN
収録物識別子タイプ ISSN
収録物識別子 0344-5607
EISSN
収録物識別子タイプ ISSN
収録物識別子 1437-2320
NII書誌ID
収録物識別子タイプ NCID
収録物識別子 AA00324143
PubMed番号
関連タイプ isVersionOf
識別子タイプ PMID
関連識別子 32951062
出版社DOI
関連タイプ isVersionOf
識別子タイプ DOI
関連識別子 10.1007/s10143-020-01392-2
著者版フラグ
出版タイプ AM
出版タイプResource http://purl.org/coar/version/c_ab4af688f83e57aa
戻る
0
views
See details
Views

Versions

Ver.1 2023-06-20 16:14:00.854397
Show All versions

Share

Mendeley Twitter Facebook Print Addthis

Cite as

エクスポート

OAI-PMH
  • OAI-PMH JPCOAR 2.0
  • OAI-PMH JPCOAR 1.0
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX

Confirm


Powered by WEKO3


Powered by WEKO3