Utility of a finger-mounted tissue oximeter with near-infrared spectroscopy to evaluate limb ischemia in patients with peripheral arterial disease

http://hdl.handle.net/10271/00003674
http://hdl.handle.net/10271/00003674
20afb48a-0f12-46da-9b0d-8dd91a697074
名前 / ファイル ライセンス アクション
DT_804ronbun.pdf 論文本文 (1.5 MB)
Item type 学位論文 / Thesis or Dissertation(1)
公開日 2019-12-10
タイトル
タイトル Utility of a finger-mounted tissue oximeter with near-infrared spectroscopy to evaluate limb ischemia in patients with peripheral arterial disease
言語 en
言語
言語 eng
キーワード
主題 limb blood flow
キーワード
主題 near-infrared spectroscopy
キーワード
主題 peripheral arterial disease
キーワード
主題 regional hemoglobin oxygen saturation
資源タイプ
資源タイプ識別子 http://purl.org/coar/resource_type/c_db06
資源タイプ doctoral thesis
アクセス権
アクセス権 open access
アクセス権URI http://purl.org/coar/access_right/c_abf2
その他のタイトル
その他のタイトル 末梢動脈疾患患者の下肢血流評価における近赤外分光法による指装着型オキシメータの有用性
著者 矢田, 達朗

× 矢田, 達朗

ja 矢田, 達朗

Search repository
書誌情報 en : Annals of Vascular Diseases

巻 12, 号 1, p. 36-43, 発行日 2019-03-25
出版者
出版者 Scientific Information Diseases
言語 en
抄録
内容記述タイプ Abstract
内容記述 Objective: To investigate whether a finger-mounted tissue oximeter is useful in evaluating limb blood flow in patients with peripheral arterial disease (PAD).
Materials and Methods: Seventy-two patients with PAD were included, and the ankle-brachial index (ABI), transcutaneous oxygen pressure (TcPO2), and skin perfusion pressure (SPP) were measured. The regional tissue oxygenation saturation (rSO2) was measured using a finger-mounted tissue oximeter at the ankle, dorsal foot, and each dorsal and plantar toe. Correlations between rSO2 and ABI and between TcPO2 and SPP were analyzed. The patients were divided into three groups: Fontaine IIa (F-IIa), IIb (F-IIb), and III and IV (F-III/IV) groups. The difference in rSO2 between each group was analyzed.
Results: Significant correlations were observed between rSO2 and TcPO2 and between rSO2 and SPP. TcPO2 and SPP in the F-III/IV group were significantly lower than those in the F-IIa group. rSO2 in the F-IIb and F-III/IV groups was significantly lower than that in the F-IIa group.
Conclusion: The measurement of rSO2 using fingermounted tissue oximetry is quick, simple, and painless. It can be used on any skin area and is useful to evaluate limb circulation in patients with PAD.
言語 en
学位名
学位名 博士(医学)
学位の区分
内容記述 doctoral
学位の分野
内容記述 医学系研究科
学位授与機関
学位授与機関識別子Scheme kakenhi
学位授与機関識別子 13802
学位授与機関名 浜松医科大学
学位授与年月日
学位授与年月日 2019-03-13
学位授与番号
学位授与番号 甲第804号
ISSN
収録物識別子タイプ PISSN
収録物識別子 1881-641X
EISSN
収録物識別子タイプ EISSN
収録物識別子 1881-6428
PubMed番号
識別子タイプ PMID
関連識別子 30931055
出版社DOI
識別子タイプ DOI
関連識別子 https://doi.org/10.3400/avd.oa.18-00117
著者版フラグ
出版タイプ VoR
出版タイプResource http://purl.org/coar/version/c_970fb48d4fbd8a85
戻る
0
views
See details
Views

Versions

Ver.1 2023-06-20 16:37:01.213386
Show All versions

Share

Mendeley Twitter Facebook Print Addthis

Cite as

エクスポート

OAI-PMH
  • OAI-PMH JPCOAR 2.0
  • OAI-PMH JPCOAR 1.0
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX

Confirm


Powered by WEKO3


Powered by WEKO3